CoChat

Time transfer to TAI using geodetic receivers

Open access
Defraigne, P, Petit, G · 2003 · Metrologia
Cited by 126

The DOI matches its Crossref record.

Abstract

The classical time transfer method used to realize International Atomic Time (TAI) is based on the common view technique, with GPS observations collected by C/A code receivers. The resulting clock offsets between the laboratory clock and GPS time are obtained from a fixed procedure defined by the Consultative Committee for Time and Frequency (CCTF). A similar procedure can be applied to the Receiver INdependent EXchange (RINEX) observation files produced by geodetic receivers driven by a stable external frequency. If the link between the receiver clock and the external clock is stable and precisely determined, the geodetic receivers can then be used for time transfer to TAI. In that case, we propose some modifications to the CCTF procedure to adapt it for the links between geodetic receivers, in order to take advantage of the P codes available on L1 and L2. This new procedure forms the ionosphere-free combination of the P1 and P2 codes as given by the 30 s RINEX observation files, the standard of the International GPS Service. The procedure is tested using the Ashtech Z-XII3T geodetic receivers and the results are compared with those obtained with the classical CCTF procedure based on the C/A code by computing the fractional frequency stability (Allan deviation) of the time links. Over short baselines, the two techniques are equivalent, while the new technique provides a factor 2 improvement for a transatlantic time link. For time links between a time receiver and a geodetic receiver, the differential satellite delays (P1-C/A or P2-C/A) must additionally be introduced. We show here that these biases do not, however, alter the long-term (>3 days) stability of the time transfer results. The corrections associated with tidal station displacement are also investigated, and the results indicate that they do not significantly improve the results at the present level of precision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/40/4/307

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 126

Metadata

Authors
Defraigne, P., & Petit, G.
Venue
Metrologia
Published
2003-06-25
Volume
40
Issue
4
Pages
184-188
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W1998636551
Cited by
126
References
0
FWCI
23.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time transfer to TAI using geodetic receivers. https://app.cochat.ai/papers/10.1088/0026-1394/40/4/307
The paper
Defraigne, P., & Petit, G. (2003). Time transfer to TAI using geodetic receivers. Metrologia. https://doi.org/10.1088/0026-1394/40/4/307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.