Particle size distributions by transmission electron microscopy: an interlaboratory comparison case study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin-Rammler-Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
Standard, S. (2006) · Cited by 6,460
Guide to the Expression of Uncertainty in Measurement
(2013) · Measurement Uncertainty and Probability · doi:10.1017/cbo9781139135085.018 · Cited by 2,767
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, | NIST
Taylor, B. N., & Kuyatt, C. E. (1993) · Cited by 514
Thomas, L., Roebben, G., Douglas, G., Calzolai, L., François, R., Gibson, P. N., & Christoph, K. (2012) · Joint Research Centre (European Commission) · doi:10.2787/63995 · Cited by 128 · cited 2×
“These quality measures can be used for a variety of applications, such as process quality control, regulation [8], and method development and validation.”
BackgroundMethodBiodistribution and biopersistence of ceria engineered nanomaterials: size dependence
Yokel, R. A., Tseng, M. T., Dan, M., Unrine, J. M., Graham, U. M., Wu, P., & Grulke, E. A. (2012) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2012.08.002 · Cited by 103
Self-citationReference materials for measuring the size of nanoparticles
Linsinger, T. P. J., Roebben, G., Solans, C., & Ramsch, R. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.09.005 · Cited by 71 · cited 1×
“There are a variety of reference materials for characterizing nanoparticle size (see [11] for lists of reference materials [12] and their sources).”
BackgroundSong, N. W., Park, K. M., Lee, I., & Huh, H. (2009) · Metrologia · doi:10.1088/0026-1394/46/5/012 · Cited by 41
Assessing nanoparticle risk poses prodigious challenges
MacPhail, R. C., Grulke, E. A., & Yokel, R. A. (2013) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1216 · Cited by 21 · cited 1×
“Toxicity can be affected by nanoparticle size [3], which makes this an important metric for risk assessment [4, 5].”
BackgroundSelf-citation
Cited by
Precise calculation of crystallite size of nanomaterials: A review
Hassanzadeh-Tabrizi, S. A. (2023) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2023.171914 · Cited by 649
Silver Nanoparticles: Technological Advances, Societal Impacts, and Metrological Challenges
Calderón-Jiménez, B., Johnson, M. E., Montoro Bustos, A. R., Murphy, K. E., Winchester, M. R., & Vega Baudrit, J. R. (2017) · Frontiers in Chemistry · doi:10.3389/fchem.2017.00006 · Cited by 342
Caputo, F., Clogston, J., Calzolai, L., Rösslein, M., & Prina-Mello, A. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.02.030 · Cited by 337
Iqbal, M. A., Tariq, A., Zaheer, A., Gul, S., Ali, S. I., Iqbal, M. Z., Akinwande, D., & Rizwan, S. (2019) · ACS Omega · doi:10.1021/acsomega.9b02359 · Cited by 228
Legal and practical challenges in classifying nanomaterials according to regulatory definitions
Miernicki, M., Hofmann, T., Eisenberger, I., von der Kammer, F., & Praetorius, A. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0396-z · Cited by 206
Metadata
- Authors
- Rice, S. B., Chan, C., Brown, S. C., Eschbach, P., Han, L., Ensor, D. S., Stefaniak, A. B., Bonevich, J., Vladár, A. E., Walker, A. R. H., Zheng, J., Starnes, C., Stromberg, A., Ye, J., & Grulke, E. A.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2013-11-27
- Volume
- 50
- Issue
- 6
- Pages
- 663-678
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W1997156967
- Cited by
- 168
- References
- 9
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.