CoChat

Time transfer by laser link (T2L2): characterization and calibration of the flight instrument

Open access
Samain, E, Vrancken, P, Guillemot, P, Fridelance, P, Exertier, P · 2014 · Metrologia
Cited by 45

The DOI matches its Crossref record.

Abstract

The T2L2 project (time transfer by laser link) allows for the synchronization of remote ultra-stable clocks over intercontinental distances (Fridelance et al 1997 Exp. Astron. 7 , Samain and Fridelance 1998 Metrologia 35 151–9 ). The principle is derived from satellite laser ranging technology with dedicated space equipment designed to record arrival times of laser pulses at the satellite. The space segment has been launched in June 2008 as a passenger experiment on the ocean altimetry satellite Jason 2. T2L2 had been specified to yield a time stability of better than 1 ps over 1000 s integration time and an accuracy of better than 100 ps. This level of performance requires a rigorous data processing which can be performed only with a comprehensive calibration model of the whole instrumentation. For this purpose, several experimental measurements have been performed before and during the integration phase of the T2L2 space instrument. This instrument model is one of the cornerstones of the data reduction process which is carried out to translate the raw information to a usable picosecond time transfer. After providing a global synopsis of the T2L2 space instrument, the paper gives a description of the experimental setup for the instrument characterization. It then details the different contributions within the calibration model and concludes with an applied example of a space to ground time transfer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/51/5/503

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 16

  1. 10.1023/A:1007982512087 · DOI
  2. Samain E, 1998, Metrologia, 35, 151, 10.1088/0026-1394/35/3/3 · DOI
  3. Samain E, 2011, Proc. European Frequency and Time Forum, 378
  4. 10.1142/S0218271808012681 · doi:10.1142/s0218271808012681
  5. 10.1109/FREQ.2007.4319284 · doi:10.1109/freq.2007.4319284
  6. 10.1016/j.asr.2010.05.015 · DOI
  7. Samain E, 2014, J. Opt.
  8. Samain E, 2002, Proc. 13th Int. Laser Ranging Workshop
  9. 10.1364/AO.37.000502 · doi:10.1364/ao.37.000502
  10. 10.1007/s00190-006-0075-3 · doi:10.1007/s00190-006-0075-3
  11. 10.1007/s00190-006-0068-2 · doi:10.1007/s00190-006-0068-2
  12. 10.1109/FREQ.2007.4319086 · doi:10.1109/freq.2007.4319086
  13. 10.1080/09500340408235273 · DOI
  14. 10.1080/09500340600791756 · doi:10.1080/09500340600791756
  15. Candelier V, 2001, Proc. EFTF, 325
  16. Exertier P, 2014, Metrologia

Cited by

See all 45

Metadata

Authors
Samain, E., Vrancken, P., Guillemot, P., Fridelance, P., & Exertier, P.
Venue
Metrologia
Published
2014-08-19
Volume
51
Issue
5
Pages
503-515
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2159205904
Cited by
45
References
0
FWCI
2.50
Type
journal article
Language
en
Open access
hybrid
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time transfer by laser link (T2L2): characterization and calibration of the flight instrument. https://app.cochat.ai/papers/10.1088/0026-1394/51/5/503
The paper
Samain, E., Vrancken, P., Guillemot, P., Fridelance, P., & Exertier, P. (2014). Time transfer by laser link (T2L2): characterization and calibration of the flight instrument. Metrologia. https://doi.org/10.1088/0026-1394/51/5/503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.