Stability comparison of two absolute gravimeters: optical versus atomic interferometers
Open accessThe DOI matches its Crossref record.
Abstract
We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter (CAG) and FG5X#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to changes in the level of vibration noise, as well as a slightly better short term stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exploring gravity with the MIGA large scale atom interferometer
Canuel, B., Bertoldi, A., Amand, L., Pozzo di Borgo, E., Chantrait, T., Danquigny, C., Dovale Álvarez, M., Fang, B., Freise, A., Geiger, R., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32165-z · Cited by 285
Self-citationContinuous Cold-Atom Inertial Sensor with1 nrad/secRotation Stability
Dutta, I., Savoie, D., Fang, B., Venon, B., Garrido Alzar, C. L., Geiger, R., & Landragin, A. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.183003 · Cited by 284
Self-citationGeophysics From Terrestrial Time‐Variable Gravity Measurements
Van Camp, M., de Viron, O., Watlet, A., Meurers, B., Francis, O., & Caudron, C. (2017) · Reviews of Geophysics · doi:10.1002/2017rg000566 · Cited by 248
“Results from laboratory tests show that the atom gravimeters provide an accuracy and precision similar to classical ballistic gravimeters (Freier et al., 2016; Gillot et al., 2014).”
BackgroundSelf-citationMobile quantum gravity sensor with unprecedented stability
Freier, C., Hauth, M., Schkolnik, V, Leykauf, B., Schilling, M., Wziontek, H., Scherneck, H.-G., Müller, J., & Peters, A. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012050 · Cited by 245
Marine Absolute Gravity Field Surveys Based on Cold Atomic Gravimeter
Wu, B., Zhang, C., Wang, K., Cheng, B., Zhu, D., Li, R., Wang, X., Lin, Q., Qiao, Z., & Zhou, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3309499 · Cited by 42
“Indeed, the performance of atomic gravime-ters (AGs) has improved greatly in the past decades and could be comparable with the best optical counterpart now [15], [16], [17], [18], [19], [20], [21], [22], [23].”
Background
Metadata
- Authors
- Gillot, P., Francis, O., Landragin, A., Pereira Dos Santos, F., & Merlet, S.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-06-25
- Volume
- 51
- Issue
- 5
- Pages
- L15-L17
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2004600120
- Cited by
- 201
- References
- 0
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stability comparison of two absolute gravimeters: optical versus atomic interferometers. https://app.cochat.ai/papers/10.1088/0026-1394/51/5/l15
- The paper
- Gillot, P., Francis, O., Landragin, A., Pereira Dos Santos, F., & Merlet, S. (2014). Stability comparison of two absolute gravimeters: optical versus atomic interferometers. Metrologia. https://doi.org/10.1088/0026-1394/51/5/l15
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.