The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A design retrospective of the DIII-D tokamak
Abstract
The DIII-D tokamak evolved from the earlier Doublet III device in 1986. Since then, the facility has undergone a number of changes including the installation of divertor baffles and pumping chambers in the vacuum vessel, the addition of a radiation shield, the development of extensive neutral beam and RF heating systems, and the addition of a comprehensive plasma control system. The facility has become the focus of a broad fusion plasma science research programme. An integrated picture of the facility and its capabilities is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Real time equilibrium reconstruction for tokamak discharge control
Ferron, J. R., Walker, M. L., Lao, L. L., John, H. E. S., Humphreys, D. A., & Leuer, J. A. (1998) · Nuclear Fusion · doi:10.1088/0029-5515/38/7/308 · Cited by 339
Locked modes in DIII-D and a method for prevention of the low density mode
Scoville, J. T., La Haye, R. J., Kellman, A. G., Osborne, T. H., Stambaugh, R. D., Strait, E. J., & Taylor, T. S. (1991) · Nuclear Fusion · doi:10.1088/0029-5515/31/5/006 · Cited by 169
Stability of high beta tokamak plasmas*
Strait, E. J. (1994) · Physics of Plasmas · doi:10.1063/1.870691 · Cited by 157
A high speed data acquisition and processing system for real time data analysis and control
Ferron, J. R. (1992) · Review of Scientific Instruments · doi:10.1063/1.1143843 · Cited by 15
Fatigue strength of inconel 625 plate and weldments used in the DIII-D configuration vacuum vessel
Trester, P. W., Kaae, J. L., & Gallix, R. (1985) · Journal of Nuclear Materials · doi:10.1016/0022-3115(85)90165-5 · Cited by 11
Cited by
Creely, A. J., Greenwald, M. J., Ballinger, S. B., Brunner, D., Canik, J., Doody, J., Fülöp, T., Garnier, D. T., Granetz, R., Gray, T. K., et al. (2020) · Journal of Plasma Physics · doi:10.1017/s0022377820001257 · Cited by 464
RMP ELM suppression in DIII-D plasmas with ITER similar shapes and collisionalities
Evans, T. E., Fenstermacher, M. E., Moyer, R. A., Osborne, T. H., Watkins, J. G., Gohil, P., Joseph, I., Schaffer, M. J., Baylor, L. R., Bécoulet, M., et al. (2008) · Nuclear Fusion · doi:10.1088/0029-5515/48/2/024002 · Cited by 397
Predicting disruptive instabilities in controlled fusion plasmas through deep learning
Kates-Harbeck, J., Svyatkovskiy, A., & Tang, W. (2019) · Nature · doi:10.1038/s41586-019-1116-4 · Cited by 367
Metadata
- Authors
- Luxon, J. L.
- Venue
- Nuclear Fusion
- Publisher
- IOP Publishing
- Published
- 2002-05
- Volume
- 42
- Issue
- 5
- Pages
- 614-633
- ISSN
- 0029-5515 (ISSN-L)
- OpenAlex
- W2027663903
- Cited by
- 528
- References
- 5
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A design retrospective of the DIII-D tokamak. https://app.cochat.ai/papers/10.1088/0029-5515/42/5/313
- The paper
- Luxon, J. L. (2002). A design retrospective of the DIII-D tokamak. Nuclear Fusion. https://doi.org/10.1088/0029-5515/42/5/313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.