The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Influence of window size in small-window colour measurement, particularly of teeth
Open accessAbstract
Tooth colour is often measured with a small window for illumination and measurement. This causes edge loss of the light, resulting in systematic errors in colour coordinates. This paper gives a quantification of the edge losses, and explains their cause. We measured reflectance spectra for 27 Formalin fixated extracted incisors using a small-window reflectance spectrophotometer equipped with external diaphragms of 3, 4, and 5 mm diameter, and using a spectroradiometer. We calculated the colour coordinates L*a*b* from these spectra. Finally, 16 randomly chosen teeth were illuminated with a pencil beam (lambda = 543 nm, and lambda = 633 nm) while the emerging light was measured as a function of distance from the illuminated spot using a CCD detector. These data were used to calculate small-window edge losses, and thus to predict the small-window reflectance factors relative to spectroradiometrically determined reflectance, at both 543 nm and 633 nm. In all instruments the same spot on the tooth was illuminated and measured, and the teeth were always wet. Colour coordinates for the small-window colour measurements deviate significantly from those determined using the spectroradiometer. These deviations can be explained from the wavelength-dependant edge loss that arises in small-window colour measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Measurement of translucency of tooth enamel and dentin
Yu, B., Ahn, J.-S., & Lee, Y.-K. (2009) · Acta Odontologica Scandinavica · doi:10.1080/00016350802577818 · Cited by 260
Measurement of discolouration of orthodontic elastomeric modules with a digital camera
Kim, S.-H., & Lee, Y.-K. (2009) · The European Journal of Orthodontics · doi:10.1093/ejo/cjp030 · Cited by 53
Metadata
- Authors
- Bolt, R. A., Bosch, J. J. T., & Coops, J. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1994-07-01
- Volume
- 39
- Issue
- 7
- Pages
- 1133-1142
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2115323740
- Cited by
- 211
- References
- 1
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of window size in small-window colour measurement, particularly of teeth. https://app.cochat.ai/papers/10.1088/0031-9155/39/7/006
- The paper
- Bolt, R. A., Bosch, J. J. T., & Coops, J. C. (1994). Influence of window size in small-window colour measurement, particularly of teeth. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/39/7/006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.