Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter

Open access
Maryanski, M J, Schulz, R J, Ibbott, G S, Gatenby, J C, Xie, J, Horton, D, Gore, J C·1994·Physics in Medicine and Biology

Abstract

A new formulation of a tissue-equivalent polymer-gel dosimeter for the measurement of three-dimensional dose distributions of ionizing radiation has been developed. It is composed of aqueous gelatin infused with acrylamide and N, N'-methylene-bisacrylamide monomers, and made hypoxic by nitrogen saturation. Irradiation of the gel, referred to as BANG, causes localized polymerization of the monomers, which, in turn, reduces the transverse NMR relaxation times of water protons. The dose dependence of the NMR transverse relaxation rate, R2, is reproducible (less than 2% variation) and is linear up to about 8 Gy, with a slope of 0.25 s(-1)Gy(-1) at 1.5 T. Magnetic resonance imaging may be used to obtain accurate three-dimensional dose distributions with high spatial resolution. Since the radiation-induced polymers do not diffuse through the gelatin matrix, the dose distributions recorded by BANG gels are stable for long periods of time, and may be used to measure low-activity radioactive sources. Since the light-scattering properties of the polymerized regions are different from those of the clear, non-irradiated regions, the dose distributions are visible, and their optical densities are dependent on dose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/39/9/010

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Metadata

Authors
Maryanski, M. J., Schulz, R. J., Ibbott, G. S., Gatenby, J. C., Xie, J., Horton, D., & Gore, J. C.
Venue
Physics in Medicine and Biology
Published
1994-09-01
Volume
39
Issue
9
Pages
1437-1455
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W1998828795
Cited by
451
References
6
FWCI
8.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter. https://app.cochat.ai/papers/10.1088/0031-9155/39/9/010
The paper
Maryanski, M. J., Schulz, R. J., Ibbott, G. S., Gatenby, J. C., Xie, J., Horton, D., & Gore, J. C. (1994). Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/39/9/010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.