The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An improved design for a stable and reproducible phantom material for use in near-infrared spectroscopy and imaging
Open accessAbstract
In this note, we describe an improved phantom material for use in near-infrared spectroscopy and imaging. The material consists of a clear epoxy resin with absorbing dyes and amorphous silica spheres as scattering particles. It is possible to calculate the scattering coefficient and angular scattering distribution of the material from Mie theory, using the known size and refractive index of the silica spheres together with the measured refractive index of the resin (approximately 1.56). We show a good agreement between prediction and experimental measurements. The scattering properties of the material closely match those of tissue in the near-infrared wavelength region, having an anisotropy factor, g, of approximately 0.93. The absorption coefficient of the epoxy is low (approximately 0.001 mm-1), and addition of the dyes produces an absorption coefficient that covers the same range as that of tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
A solid tissue phantom for photon migration studies
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A., & Valentini, G. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/011 · Cited by 289
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Self-citationJones, B., Dat, M., & Cooper, C. E. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.12.127002 · Cited by 37
Metadata
- Authors
- Firbank, M., Oda, M., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1995-05-01
- Volume
- 40
- Issue
- 5
- Pages
- 955-961
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2040094260
- Cited by
- 181
- References
- 1
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An improved design for a stable and reproducible phantom material for use in near-infrared spectroscopy and imaging. https://app.cochat.ai/papers/10.1088/0031-9155/40/5/016
- The paper
- Firbank, M., Oda, M., & Delpy, D. T. (1995). An improved design for a stable and reproducible phantom material for use in near-infrared spectroscopy and imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/40/5/016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.