The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A comparison of two methods for measuring the signal to noise ratio on MR images
Open accessAbstract
The signal to noise ratio (SNR) is one of the important measures of the performance of a magnetic resonance imaging (MRI) system. The object of this study was to compare a single acquisition method, which estimates the noise from background pixels, with a dual acquisition method which estimates the noise from the subtraction of two sequentially acquired images. The dual acquisition method is more exact, but is slower to perform and requires image manipulation. A comparison between the two methods gave a good correlation, and a regression equation of SNRsingle = 1.1 + 0.94 SNRdual. The single acquisition method is therefore appropriate for use in a quality assurance programme, since it is quicker and simpler to perform and is a good indicator of the more exact measure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring signal-to-noise ratios in MR imaging.
Kaufman, L., Kramer, D. M., Crooks, L. E., & Ortendahl, D. A. (1989) · Radiology · doi:10.1148/radiology.173.1.2781018 · Cited by 360
Price, R. R., Axel, L., Morgan, T., Newman, R., Perman, W., Schneiders, N., Selikson, M., Wood, M., & Thomas, S. R. (1990) · Medical Physics · doi:10.1118/1.596566 · Cited by 308
Sources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277
Estimation of the Noise in Magnitude MR Images
Sijbers, J., den Dekker, A. J., Van Audekerke, J., Verhoye, M., & Van Dyck, D. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00199-9 · Cited by 277
Correction of intensity nonuniformity in MR images of any orientation
Wicks, D., Barker, G. J., & Tofts, P. S. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90023-7 · Cited by 155
II. Performance assessment and quality control in MRI by Eurospin test objects and protocols
Lerski, R. A., & de Certaines, J. D. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90199-n · Cited by 112
Cited by
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Introduction to Microwave Imaging
Nikolova, N. K. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316084267 · Cited by 263
Militello, C., Rundo, L., Toia, P., Conti, V., Russo, G., Filorizzo, C., Maffei, E., Cademartiri, F., La Grutta, L., Midiri, M., et al. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103424 · Cited by 71
“(5) [48][49].”
Metadata
- Authors
- Firbank, M. J., Coulthard, A., Harrison, R. M., & Williams, E. D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-11-22
- Volume
- 44
- Issue
- 12
- Pages
- N261-N264
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2058452916
- Cited by
- 256
- References
- 7
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.