The DOI matches its Crossref record.
Three-dimensional sonoelastography: principles and practices
Abstract
Sonoelastography is an ultrasound imaging technique where low amplitude, low-frequency shear waves (less than 0.1 mm displacement and less than 1 kHz frequency) are propagated through internal organs, while real-time Doppler techniques are used to image the resulting vibration pattern. When a discrete hard inhomogeneity, such as a tumour, is present within a region of soft tissue, a decrease in the vibration amplitude will occur at its location. This forms the basis for tumour detection using sonoelastography. For three-dimensional (3D) imaging the acquisition of sequential tomographic slices using this technique, combined with image segmentation, enables the reconstruction, quantification and visualization of tumour volumes. Sonoelastography and magnetic resonance images (MRI) of a tissue phantom containing a hard isoechoic inclusion are compared to evaluate the accuracy of this method. The tumour delineation from sonoelastography was found to have good agreement with the tumour from MRI except for a bleeding at one of its ends. Although sonoelastography is still in an experimental phase, the principles behind this imaging modality are explained and some practical aspects of acquiring sonoelastography images are described. Results from a 3D sonoelastography reconstruction of a tissue mimicking phantom and an ex vivo whole prostate specimen are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Self-citationBavu, É., Gennisson, J.-L., Couade, M., Bercoff, J., Mallet, V., Fink, M., Badel, A., Vallet-Pichard, A., Nalpas, B., Tanter, M., et al. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.016 · Cited by 415
Sikdar, S., Shah, J. P., Gebreab, T., Yen, R.-H., Gilliams, E., Danoff, J., & Gerber, L. H. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.04.015 · Cited by 362
Metadata
- Authors
- Taylor, L. S., Porter, B. C., Rubens, D. J., & Parker, K. J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-05-19
- Volume
- 45
- Issue
- 6
- Pages
- 1477-1494
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2120073256
- Cited by
- 168
- References
- 0
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional sonoelastography: principles and practices. https://app.cochat.ai/papers/10.1088/0031-9155/45/6/306
- The paper
- Taylor, L. S., Porter, B. C., Rubens, D. J., & Parker, K. J. (2000). Three-dimensional sonoelastography: principles and practices. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/45/6/306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.