Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record.

Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†

Hueber, D M, Franceschini, M A, Ma, H Y, Zhang, Q, Ballesteros, J R, Fantini, S, Wallace, D, Ntziachristos, V, Chance, B · 2001 · Physics in Medicine and Biology

Abstract

The frequency-domain multiple-distance (FDMD) method is capable of measuring the absolute absorption and reduced scattering coefficients of optically turbid media. Absolute measurement of absorption at two near-infrared (NIR) wavelengths makes possible the quantitation of tissue haemoglobin concentration and tissue haemoglobin oxygen-saturation (StO2). However, errors are introduced by the uncertainties of background absorption and the dissimilarities between real tissues and the simplified mathematical model on which these measurements are based. An FDMD-based tissue instrument has been used for the monitoring of tissue haemoglobin concentration and oxygenation in the brain of newborn piglets during periods of hypoxia and hyperoxia. These tissue haemoglobin saturation values were compared with arterial saturation (SaO2) and venous saturation (SvO2) measured by blood gas analyses. A linear correlation was observed between StO2 and the average of SaO2 and SvO2. However, StO2 is not equal to any fixed weighted average of SaO2 and SvO2 unless we introduce an effective background tissue absorption. The magnitude of the background absorption was about 0.08 cm(-1) at 758 nm and 0.06 cm(-1) at 830 nm, and it was nearly consistent between piglets. The origin of this 'effective' background absorption may be real, an artefact caused by the application of a simplified model to a complex sample, or a combination of factors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/46/1/304

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B.
Venue
Physics in Medicine and Biology
Published
2000-11-30
Volume
46
Issue
1
Pages
41-62
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2169426316
Cited by
158
References
0
FWCI
3.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†. https://app.cochat.ai/papers/10.1088/0031-9155/46/1/304
The paper
Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B. (2001). Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/1/304

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.