The DOI matches its Crossref record.
Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†
Abstract
The frequency-domain multiple-distance (FDMD) method is capable of measuring the absolute absorption and reduced scattering coefficients of optically turbid media. Absolute measurement of absorption at two near-infrared (NIR) wavelengths makes possible the quantitation of tissue haemoglobin concentration and tissue haemoglobin oxygen-saturation (StO2). However, errors are introduced by the uncertainties of background absorption and the dissimilarities between real tissues and the simplified mathematical model on which these measurements are based. An FDMD-based tissue instrument has been used for the monitoring of tissue haemoglobin concentration and oxygenation in the brain of newborn piglets during periods of hypoxia and hyperoxia. These tissue haemoglobin saturation values were compared with arterial saturation (SaO2) and venous saturation (SvO2) measured by blood gas analyses. A linear correlation was observed between StO2 and the average of SaO2 and SvO2. However, StO2 is not equal to any fixed weighted average of SaO2 and SvO2 unless we introduce an effective background tissue absorption. The magnitude of the background absorption was about 0.08 cm(-1) at 758 nm and 0.06 cm(-1) at 830 nm, and it was nearly consistent between piglets. The origin of this 'effective' background absorption may be real, an artefact caused by the application of a simplified model to a complex sample, or a combination of factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Metadata
- Authors
- Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-11-30
- Volume
- 46
- Issue
- 1
- Pages
- 41-62
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2169426316
- Cited by
- 158
- References
- 0
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†. https://app.cochat.ai/papers/10.1088/0031-9155/46/1/304
- The paper
- Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B. (2001). Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument†. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/1/304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.