Time resolved optical tomography of the human forearm
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A 32-channel time-resolved optical imaging instrument has been developed principally to study functional parameters of the new-born infant brain. As a prelude to studies on infants, the device and image reconstruction methodology have been evaluated on the adult human forearm. Cross-sectional images were generated using time-resolved measurements of transmitted light at two wavelengths. All data were acquired using a fully automated computer-controlled protocol. Images representing the internal scattering and absorbing properties of the arm are presented, as well as images that reveal physiological changes during a simple finger flexion exercise. The results presented in this paper represent the first simultaneous tomographic reconstruction of the internal scattering and absorbing properties of a clinical subject using purely temporal data, with additional co-registered difference images showing repeatable absorption changes at two wavelengths in response to exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 2×
“Taken from Simpson et al (1998), Firbank et al (1993), Cheong et al (1990) and the spectra in figure 3.”
BackgroundMethod
Cited by
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationPrinciples, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Self-citationFerrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Metadata
- Authors
- Hillman, E. M. C., Hebden, J. C., Schweiger, M., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-03-21
- Volume
- 46
- Issue
- 4
- Pages
- 1117-1130
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2087324007
- Cited by
- 146
- References
- 1
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time resolved optical tomography of the human forearm. https://app.cochat.ai/papers/10.1088/0031-9155/46/4/315
- The paper
- Hillman, E. M. C., Hebden, J. C., Schweiger, M., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. R. (2001). Time resolved optical tomography of the human forearm. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/4/315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.