Performance evaluation of the microPET P4: a PET system dedicated to animal imaging
Abstract
The microPET Primate 4-ring system (P4) is an animal PET tomograph with a 7.8 cm axial extent, a 19 cm diameter transaxial field of view (FOV) and a 22 cm animal port. The system is composed of 168 detector modules, each with an 8 x 8 array of 2.2 x 2.2 x 10 mm3 lutetium oxyorthosilicate crystals, arranged as 32 crystal rings 26 cm in diameter. The detector crystals are coupled to a Hamamatsu R5900-C8 PS-PMT via a 10 cm long optical fibre bundle. The detectors have a timing resolution of 3.2 ns, an average energy resolution of 26%, and an average intrinsic spatial resolution of 1.75 mm. The system operates in 3D mode without inter-plane septa, acquiring data in list mode. The reconstructed image spatial resolution ranges from 1.8 mm at the centre to 3 mm at 4 cm radial offset. The tomograph has a peak system sensitivity of 2.25% at the centre of the FOV with a 250-750 keV energy window. The noise equivalent count rate peaks at 100-290 kcps for representative object sizes. Images from two phantoms and three different types of laboratory animal demonstrate the advantage of the P4 system over the original prototype microPET. including its threefold improvement in sensitivity and a large axial FOV sufficient to image an entire mouse in a single bed position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Self-citationAlexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 465
Self-citation(2005) · PubMed · Cited by 395
Jong, H. W. A. M. D., Velden, F. H. P. V., Kloet, R. W., Buijs, F. L., Boellaard, R., & Lammertsma, A. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/019 · Cited by 349
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Self-citation
Metadata
- Authors
- Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-06-21
- Volume
- 46
- Issue
- 7
- Pages
- 1845-1862
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2160463229
- Cited by
- 308
- References
- 0
- FWCI
- 25.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. https://app.cochat.ai/papers/10.1088/0031-9155/46/7/308
- The paper
- Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R. (2001). Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/7/308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.