The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vivo optical characterization of human tissues from 610 to 1010 nm by time-resolved reflectance spectroscopy
Abstract
A fully automated system for time-resolved reflectance spectroscopy based on tunable mode-locked laser sources and on time-correlated single-photon counting for the detection of time-resolved reflectance data was applied to the evaluation of the optical properties of biological tissues (arm, abdomen and forehead) in vivo from 610 to 1010 nm. The scattering decreases progressively with increasing wavelength, while the absorption line shapes show the typical spectral features of the principal tissue components (haemoglobin, water and lipid), with different weights depending on the tissue type. The best fit of the absorption spectra measured in vivo with the spectra of the pure constituents yielded information on the percentage composition of the different tissues. The interpretation of transport scattering spectra with Mie theory provided information on tissue structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
The modified Beer–Lambert law revisited
Kocsis, L., Herman, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 679
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Metadata
- Authors
- Torricelli, A., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-07-18
- Volume
- 46
- Issue
- 8
- Pages
- 2227-2237
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1991918711
- Cited by
- 173
- References
- 1
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo optical characterization of human tissues from 610 to 1010 nm by time-resolved reflectance spectroscopy. https://app.cochat.ai/papers/10.1088/0031-9155/46/8/313
- The paper
- Torricelli, A., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R. (2001). In vivo optical characterization of human tissues from 610 to 1010 nm by time-resolved reflectance spectroscopy. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/8/313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.