The DOI matches its Crossref record.
All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry
Open accessAbstract
The MAX (Male Adult voXel) phantom has been developed from existing segmented images of a male adult body, in order to achieve a representation as close as possible to the anatomical properties of the reference adult male specified by the ICRP. The study describes the adjustments of the soft-tissue organ masses, a new dosimetric model for the skin, a new model for skeletal dosimetry and a computational exposure model based on coupling the MAX phantom with the EGS4 Monte Carlo code. Conversion coefficients between equivalent dose to the red bone marrow as well as effective MAX dose and air-kerma free in air for external photon irradiation from the front and from the back, respectively, are presented and compared with similar data from other human phantoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Converting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513
Realistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Simonsen, L. C., Slaba, T. C., Guida, P., & Rusek, A. (2020) · PLOS Biology · doi:10.1371/journal.pbio.3000669 · Cited by 263
“[13,16,17], vehicle computer-aided design (CAD) geometries, and human phantoms [15,18,19].”
BackgroundMethod
Metadata
- Authors
- Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-05-07
- Volume
- 48
- Issue
- 10
- Pages
- 1239-1262
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2063018753
- Cited by
- 239
- References
- 0
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry. https://app.cochat.ai/papers/10.1088/0031-9155/48/10/301
- The paper
- Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003). All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/48/10/301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.