All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The MAX (Male Adult voXel) phantom has been developed from existing segmented images of a male adult body, in order to achieve a representation as close as possible to the anatomical properties of the reference adult male specified by the ICRP. The study describes the adjustments of the soft-tissue organ masses, a new dosimetric model for the skin, a new model for skeletal dosimetry and a computational exposure model based on coupling the MAX phantom with the EGS4 Monte Carlo code. Conversion coefficients between equivalent dose to the red bone marrow as well as effective MAX dose and air-kerma free in air for external photon irradiation from the front and from the back, respectively, are presented and compared with similar data from other human phantoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Report of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Photon mass attenuation and energy-absorption coefficients
Hubbell, J. H. (1982) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/0020-708x(82)90248-4 · Cited by 1,459
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Conversion coefficients for use in radiological protection against external radiation.
Smith, H. G. (1997) · Cited by 901
Basic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364 · cited 1×
“After a method introduced by Zankl and Wittmann (2001) the information held by the CT numbers (= grey values) of the skeletal pixels in the CT images of the scanned patient can be used to design a voxel-specific distribution of bone marrow.”
MethodRichmond, C. R. (1985) · International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine · doi:10.1080/09553008514551281 · Cited by 305
The GSF family of voxel phantoms
Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/307 · Cited by 280
Voxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213 · cited 1×
“Caon et al (1997, 1999) developed a voxel phantom of a 14 year old girl, Saito et al (2001) segmented whole-body CT data of a patient whose external dimensions were in good agreement with the Japanese Reference Man (Tanaka et al 1989), and Xu et al (2000) segmented colour photographs of the Visible Human Male (Spitzer…”
MethodKAWAMURA, H. (1996) · Japanese Journal of Health Physics · doi:10.5453/jhps.31.418 · Cited by 209
The adult male voxel model ”Golem" segmented from whole-body CT patient data
Zankl, M., & Wittmann, A. (2001) · Radiation and Environmental Biophysics · doi:10.1007/s004110100094 · Cited by 207 · cited 2×
“9 kg (Zankl and Wittmann 2001), which could be one reason for the relatively high skeletal doses, because GOLEM’s bones experience less shielding from surrounding tissues.”
BackgroundMethodStabin, M. G., Watson, E. E., Cristy, M., Ryman, J. C., Eckerman, K. F., Davis, J. L., Marshall, D., & Gehlen, M. K. (1995) · doi:10.2172/91944 · Cited by 194 · cited 1×
“Later arms and legs, segmented from the Visible Man’s red colour cross-sections (Spitzer and Whitlock 1998), have been added by Stuchly (1996) to the torso phantom, which then was called MANTISSUE3-6.”
MethodAn instrumented phantom system for analog computation of treatment plans.
Alderson, S. W., Lanzl, L. H., ROLLINS, M., & SPIRA, J. (1962) · PubMed · Cited by 190
Organ dose conversion coefficients for external photon irradiation of male and female voxel models
Zankl, M., Fill, U., Petoussi-Henss, N., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/14/301 · Cited by 162
Caon, M., Bibbo, G., & Pattison, J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/9/309 · Cited by 123
Fill, U. A., Zankl, M., Petoussi-Henss, N., Siebert, M., & Regulla, D. F. (2004) · Health Physics · doi:10.1097/00004032-200403000-00003 · Cited by 111
Jones, D. G. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032072 · Cited by 105 · cited 8×
“Zubal et al (1994a, 1994b, 1995) segmented CT and MRI data of a patient who was scanned from head to mid-thigh, and Dimbylow (1995) introduced the voxel phantom NORMAN based on MRI data of a healthy volunteer. The voxel dimensions have been scaled to match the body height and weight of the Reference Man (ICRP 1975), t…”
BackgroundMethodInfluentialThe application of voxel phantoms to the internal dosimetry of radionuclides
Zankl, M., Petoussi-Henss, N., Fill, U. A., & Regulla, D. F. (2003) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006299 · Cited by 100
Chao, T., Bozkurt, A., & Xu, X. G. (2001) · Health Physics · doi:10.1097/00004032-200108000-00010 · Cited by 98
Osiris: a medical image-manipulation system.
Ligier, Y., Ratib, O. M., Logean, M., & Girard, C. (1994) · PubMed · Cited by 70
DISTRIBUTION OF DOSE IN THE BODY FROM A SOURCE OF GAMMA RAYS DISTRIBUTED UNIFORMLY IN AN ORGAN
Hl, F., & Snyder, W. S. (1968) · Elsevier eBooks · doi:10.1016/b978-1-4832-8312-8.50220-4 · Cited by 68
Smith, T., Petoussi-Henss, N., & Zankl, M. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000294 · Cited by 57
Kramer, R. A., Vieira, J. W., Khoury, H. J., & Lima, F. R. D. A. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/6/002 · Cited by 57
Self-citationConsiderations of marrow cellularity in 3-dimensional dosimetric models of the trabecular skeleton.
Bolch, W. E., Patton, P. W., Rajon, D. A., Shah, A. P., Jokisch, D. W., & Inglis, B. A. (2002) · PubMed · Cited by 54
PHOTON SPECIFIC ABSORBED FRACTIONS CALCULATED IN THE TRUNK OF AN ADULT MALE VOXEL-BASED PHANTOM
Stabin, M. G., & Yoriyaz, H. (2002) · Health Physics · doi:10.1097/00004032-200201000-00005 · Cited by 51
van Dyck, C. H., Tan, P., Baldwin, R. M., Amici, L. A., Garg, P., Ng, C. K., Soufer, R., Charney, D. S., & Innis, R. B. (2000) · PubMed · Cited by 46
Márquez, G., Wang, L. V., Wang, C., & Hu, Z. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/1/022 · Cited by 27
Cited by
Converting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513
Realistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Simonsen, L. C., Slaba, T. C., Guida, P., & Rusek, A. (2020) · PLOS Biology · doi:10.1371/journal.pbio.3000669 · Cited by 263
“[13,16,17], vehicle computer-aided design (CAD) geometries, and human phantoms [15,18,19].”
BackgroundMethod
Metadata
- Authors
- Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-05-07
- Volume
- 48
- Issue
- 10
- Pages
- 1239-1262
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2063018753
- Cited by
- 239
- References
- 30
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.