A kinetic model for dynamic [18F]-Fmiso PET data to analyse tumour hypoxia
Open accessAbstract
A method is presented to identify and quantify hypoxia in human head-and-neck tumours based on dynamic [18F]-Fmiso PET patient data, using a model for the tracer transport. A compartmental model was developed, inspired by recent immunohistochemical investigations with the tracer pimonidazole. In order to take the trapping of the tracer and the diffusion in interstitial space into account, the kinetic model consists of two compartments and a specific input function. This voxel-based data analysis allows us to decompose the time-activity curves (TACs) into their perfusion, diffusion and hypoxia-induced retention components. This characterization ranges from well perfused tumours over diffusion limited hypoxia to strong hypoxia and necrosis. The overall shape of the TAC and the model parameters may point at the structural architecture of the tissue sample. The model addresses the two main problems associated with hypoxia imaging with PET. Firstly, the hypoxic areas are spatially separated from well perfused vessels, causing long diffusion times of the tracer. Secondly, tracer uptake occurs only in viable hypoxic cells, which constitute only a small subpopulation in the presence of necrosis. The resulting parameters such as the concentration of hypoxic cells and the perfusion are displayed in parameter plots ('hypoxia map'). Quantification of hypoxia performed with the presented kinetic model is more reliable than a criterion based on static standardized uptake values (SUV) at an early timepoint, because severely hypoxic/necrotic tissues show low uptake and are thus overlooked by SUV threshold identification. The derived independent measures for perfusion and hypoxia may provide a basis for individually adapted treatment planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Use of PET and PET/CT for Radiation Therapy Planning: IAEA expert report 2006–2007
MacManus, M., Nestle, U., Rosenzweig, K. E., Carrio, I., Messa, C., Belohlavek, O., Danna, M., Inoue, T., Deniaud-Alexandre, E., Schipani, S., et al. (2009) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.11.008 · Cited by 367
Hypoxia Dose Painting by Numbers: A Planning Study
Thorwarth, D., Eschmann, S.-M., Paulsen, F., & Alber, M. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.11.061 · Cited by 301
Self-citationPET/MRI for Neurologic Applications
Catana, C., Drzezga, A., Heiss, W.-D., & Rosen, B. R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105346 · Cited by 288
Ramamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
Metadata
- Authors
- Thorwarth, D., Eschmann, S. M., Paulsen, F., & Alber, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-04-27
- Volume
- 50
- Issue
- 10
- Pages
- 2209-2224
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2048619131
- Cited by
- 164
- References
- 0
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A kinetic model for dynamic [18F]-Fmiso PET data to analyse tumour hypoxia. https://app.cochat.ai/papers/10.1088/0031-9155/50/10/002
- The paper
- Thorwarth, D., Eschmann, S. M., Paulsen, F., & Alber, M. (2005). A kinetic model for dynamic [18F]-Fmiso PET data to analyse tumour hypoxia. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/50/10/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.