Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapy
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
A greyscale-based fully automatic deformable image registration algorithm, originally known as the 'demons' algorithm, was implemented for CT image-guided radiotherapy. We accelerated the algorithm by introducing an 'active force' along with an adaptive force strength adjustment during the iterative process. These improvements led to a 40% speed improvement over the original algorithm and a high tolerance of large organ deformations. We used three methods to evaluate the accuracy of the algorithm. First, we created a set of mathematical transformations for a series of patient's CT images. This provides a 'ground truth' solution for quantitatively validating the deformable image registration algorithm. Second, we used a physically deformable pelvic phantom, which can measure deformed objects under different conditions. The results of these two tests allowed us to quantify the accuracy of the deformable registration. Validation results showed that more than 96% of the voxels were within 2 mm of their intended shifts for a prostate and a head-and-neck patient case. The mean errors and standard deviations were 0.5 mm+/-1.5 mm and 0.2 mm+/-0.6 mm, respectively. Using the deformable pelvis phantom, the result showed a tracking accuracy of better than 1.5 mm for 23 seeds implanted in a phantom prostate that was deformed by inflation of a rectal balloon. Third, physician-drawn contours outlining the tumour volumes and certain anatomical structures in the original CT images were deformed along with the CT images acquired during subsequent treatments or during a different respiratory phase for a lung cancer case. Visual inspection of the positions and shapes of these deformed contours agreed well with human judgment. Together, these results suggest that the accelerated demons algorithm has significant potential for delineating and tracking doses in targets and critical structures during CT-guided radiotherapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676 · cited 1×
“The functional imaging laboratory at University of London developed statistical parametric mapping (SPM) tools (http://www.fil.ion.ucl.ac.uk/spm/), which also included a deformable model using a discrete cosine basis set (Wright et al 1995, Ashburner and Friston 1999, 2000).”
MethodPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
A pyramid approach to subpixel registration based on intensity
Thevenaz, P., Ruttimann, U. E., & Unser, M. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.650848 · Cited by 3,078
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445 · cited 9×
“…(voxel) to a reference CT image for dose tracking or replanning (Yan et al 1999, Lockman et al 2000, Liang and Yan 2003, Brock et al 2002, 2003, Meyer et al 1997, Joshi et al 2002, Joshi and Miller 2000, Valverde et al 2001, Metaxas and Kakadiaris 2002, Tichavsky and Wong 2002, Thirion 1996, 1998).”
BackgroundMethodInfluentialNonlinear spatial normalization using basis functions
Ashburner, J., & Friston, K. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:4<254::aid-hbm4>3.0.co;2-g · Cited by 1,884
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Automated Image Registration: II. Intersubject Validation of Linear and Nonlinear Models
Woods, R. P., Grafton, S. T., Watson, J. D. G., Sicotte, N. L., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00028 · Cited by 994
Ezzell, G. A., Galvin, J. M., Low, D. A., Palta, J. R., Rosen, I., Sharpe, M. B., Xia, P., Xiao, Y., Xing, L., & Yu, C. (2003) · Medical Physics · doi:10.1118/1.1591194 · Cited by 983
Performance of optical flow techniques
Barron, J. L., Fleet, D. J., Beauchemin, S. S., & Burkitt, T. A. (2003) · Proceedings 1992 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1992.223269 · Cited by 743
Wright, I. C., McGuire, P. K., Poline, J.-B., Travere, J. M., Murray, R. M., Frith, C. D., Frackowiak, R. S. J., & Friston, K. J. (1995) · NeuroImage · doi:10.1006/nimg.1995.1032 · Cited by 530
Landmark matching via large deformation diffeomorphisms
Joshi, S. C., & Miller, M. I. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.855431 · Cited by 501
Image guidance for precise conformal radiotherapy
Mackie, T. R., Kapatoes, J., Ruchala, K., Lu, W., Wu, C., Olivera, G., Forrest, L., Tome, W., Welsh, J., Jeraj, R., et al. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00090-7 · Cited by 484
Meyer, C. R., Boes, J. L., Kim, B., Bland, P. H., Zasadny, K. R., Kison, P. V., Koral, K., Frey, K. A., & Wahl, R. L. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85010-4 · Cited by 460
Fast Fluid Registration of medical images
Bro-Nielsen, M., & Gramkow, C. (1996) · Lecture Notes in Computer Science · doi:10.1007/bfb0046964 · Cited by 395
Fast free-form deformable registration via calculus of variations
Lu, W., Chen, M.-L., Olivera, G. H., Ruchala, K. J., & Mackie, T. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/003 · Cited by 259
Guimond, A., Roche, A., Ayache, N., & Meunier, J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906425 · Cited by 215
Non-rigid matching using demons
Thirion, J.-P. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517081 · Cited by 197
Wang, H., Dong, L., Lii, M. F., Lee, A. L., de Crevoisier, R., Mohan, R., Cox, J. D., Kuban, D. A., & Cheung, R. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.07.677 · Cited by 181
Self-citationMultiscale deformable model segmentation and statistical shape analysis using medial descriptions
Joshi, S. C., Pizer, S. M., Fletcher, P. T., Yushkevich, P. A., Thall, A., & Marron, J. S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009389 · Cited by 148
Tracking the dose distribution in radiation therapy by accounting for variable anatomy
Schaly, B., Kempe, J., Bauman, G. S., Battista, J. J., & Dyk, J. V. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/5/010 · Cited by 146
Inclusion of organ deformation in dose calculations
Brock, K. K., McShan, D. L., Haken, R. K. T., Hollister, S. J., Dawson, L. A., & Balter, J. M. (2003) · Medical Physics · doi:10.1118/1.1539039 · Cited by 146
Reliable and Efficient Computation of Optical Flow
Lai, S., & Vemuri, B. C. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008005509994 · Cited by 97
Ford, E. C., Chang, J., Mueller, K. D., Sidhu, K., Todor, D. A., Mageras, G. S., Yorke, E. D., Ling, C., & Amols, H. I. (2002) · Medical Physics · doi:10.1118/1.1517614 · Cited by 92
Self-citationTechnical note: Creating a four‐dimensional model of the liver using finite element analysis
Brock, K. K., Hollister, S. J., Dawson, L. A., & Balter, J. M. (2002) · Medical Physics · doi:10.1118/1.1485055 · Cited by 68
Elastically adaptive deformable models
Metaxas, D., & Kakadiaris, I. A. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2002.1039203 · Cited by 68
Reducing uncertainties in volumetric image based deformable organ registration
Liang, J., & Yan, D. (2003) · Medical Physics · doi:10.1118/1.1587631 · Cited by 58
Court, L. E., Dong, L., Taylor, N., Ballo, M. T., Kitamura, K., Lee, A. K., O'Daniel, J. C., White, R. A., Cheung, R. M., & Kuban, D. A. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.023 · Cited by 54
Self-citationTwo algorithms for non-rigid image registration and their evaluation
Xie, Z., Ng, L., & Gee, J. C. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.481381 · Cited by 11
Cited by
Diffeomorphic demons: Efficient non-parametric image registration
Vercauteren, T., Pennec, X., Perchant, A., & Ayache, N. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.040 · Cited by 1,592
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
Metadata
- Authors
- Wang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-06-01
- Volume
- 50
- Issue
- 12
- Pages
- 2887-2905
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1990885164
- Cited by
- 610
- References
- 29
- FWCI
- 26.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.