The DOI matches its Crossref record.
X-ray computed tomography
Open accessAbstract
X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The production of anatomical teaching resources using three‐dimensional (3D) printing technology
McMenamin, P. G., Quayle, M. R., McHenry, C. R., & Adams, J. W. (2014) · Anatomical Sciences Education · doi:10.1002/ase.1475 · Cited by 698
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
Light Sheet Fluorescence Microscopy: A Review
Santi, P. A. (2011) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155410394857 · Cited by 431
X-ray-activated nanosystems for theranostic applications
Chen, X., Song, J., Chen, X., & Yang, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00921j · Cited by 401
A review of imaging techniques for systems biology
Kherlopian, A. R., Song, T., Duan, Q., Neimark, M. A., Po, M. J., Gohagan, J. K., & Laine, A. F. (2008) · BMC Systems Biology · doi:10.1186/1752-0509-2-74 · Cited by 310
Metadata
- Authors
- Kalender, W. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-06-20
- Volume
- 51
- Issue
- 13
- Pages
- R29-R43
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2157666152
- Cited by
- 689
- References
- 0
- FWCI
- 13.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray computed tomography. https://app.cochat.ai/papers/10.1088/0031-9155/51/13/r03
- The paper
- Kalender, W. A. (2006). X-ray computed tomography. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/51/13/r03
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.