Anisotropic photon migration in human skeletal muscle
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
It is demonstrated in the short head of the human biceps brachii of 16 healthy subjects (12 males and 4 females) that near infrared photon migration is anisotropic. The probability for a photon to travel along the direction of the muscle fibres is higher (approximately 0.4) than that of travelling along a perpendicular axis (approximately 0.3) while in the adipose tissue the probability is the same (approximately 0.33) in all directions. Considering that the muscle fibre orientation is different depending on the type of muscle considered, and that inside a given skeletal muscle the orientation may change, the present findings in part might explain the intrasubject variability observed in the physiological parameters measured by near infrared spectroscopy techniques. In other words, the observed regional differences might not only be physiological differences but also optical artefacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Self-citation
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Meat quality assessment using biophysical methods related to meat structure
Damez, J.-L., & Clerjon, S. (2008) · Meat Science · doi:10.1016/j.meatsci.2008.05.039 · Cited by 280
“Refocusing on muscle studies, Binzoni et al. (2006) worked on anisotropic photon migration in human skeletal muscle as a tool to access information on fibre organization.”
Background
Metadata
- Authors
- Binzoni, T., Courvoisier, C., Giust, R., Tribillon, G., Gharbi, T., Hebden, J. C., Leung, T. S., Roux, J., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-02-15
- Volume
- 51
- Issue
- 5
- Pages
- N79-N90
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1965555065
- Cited by
- 44
- References
- 2
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anisotropic photon migration in human skeletal muscle. https://app.cochat.ai/papers/10.1088/0031-9155/51/5/n01
- The paper
- Binzoni, T., Courvoisier, C., Giust, R., Tribillon, G., Gharbi, T., Hebden, J. C., Leung, T. S., Roux, J., & Delpy, D. T. (2006). Anisotropic photon migration in human skeletal muscle. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/51/5/n01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.