The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Open accessAbstract
The recent emergence of various types of flat-panel x-ray detectors and C-arm gantries now enables the construction of novel imaging platforms for a wide variety of clinical applications. Many of these applications require interactive 3D image generation, which cannot be satisfied with inexpensive PC-based solutions using the CPU. We present a solution based on commodity graphics hardware (GPUs) to provide these capabilities. While GPUs have been employed for CT reconstruction before, our approach provides significant speedups by exploiting the various built-in hardwired graphics pipeline components for the most expensive CT reconstruction task, backprojection. We show that the timings so achieved are superior to those obtained when using the GPU merely as a multi-processor, without a drop in reconstruction quality. In addition, we also show how the data flow across the graphics pipeline can be optimized, by balancing the load among the pipeline components. The result is a novel streaming CT framework that conceptualizes the reconstruction process as a steady flow of data across a computing pipeline, updating the reconstruction result immediately after the projections have been acquired. Using a single PC equipped with a single high-end commodity graphics board (the Nvidia 8800 GTX), our system is able to process clinically-sized projection data at speeds meeting and exceeding the typical flat-panel detector data production rates, enabling throughput rates of 40-50 projections s(-1) for the reconstruction of 512(3) volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
The Design and Implementation of FFTW3
Frigo, M., & Johnson, S. G. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2004.840301 · Cited by 5,086
Cited by
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Pan, X., Sidky, E. Y., & Vannier, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123009 · Cited by 572
A review on CT image noise and its denoising
Diwakar, M., & Kumar, M. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.01.010 · Cited by 416
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Low-dose CT reconstruction via edge-preserving total variation regularization
Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/011 · Cited by 396
Metadata
- Authors
- Xu, F., & Mueller, K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-05-17
- Volume
- 52
- Issue
- 12
- Pages
- 3405-3419
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2159940799
- Cited by
- 223
- References
- 2
- FWCI
- 16.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time 3D computed tomographic reconstruction using commodity graphics hardware. https://app.cochat.ai/papers/10.1088/0031-9155/52/12/006
- The paper
- Xu, F., & Mueller, K. (2007). Real-time 3D computed tomographic reconstruction using commodity graphics hardware. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/52/12/006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.