The DOI matches its Crossref record.
Acoustical properties of selected tissue phantom materials for ultrasound imaging
Open accessAbstract
This note summarizes the characterization of the acoustic properties of four materials intended for the development of tissue, and especially breast tissue, phantoms for the use in photoacoustic and ultrasound imaging. The materials are agar, silicone, polyvinyl alcohol gel (PVA) and polyacrylamide gel (PAA). The acoustical properties, i.e., the speed of sound, impedance and acoustic attenuation, are determined by transmission measurements of sound waves at room temperature under controlled conditions. Although the materials are tested for application such as photoacoustic phantoms, we focus here on the acoustic properties, while the optical properties will be discussed elsewhere. To obtain the acoustic attenuation in a frequency range from 4 MHz to 14 MHz, two ultrasound sources of 5 MHz and 10 MHz core frequencies are used. For preparation, each sample is cast into blocks of three different thicknesses. Agar, PVA and PAA show similar acoustic properties as water. Within silicone polymer, a significantly lower speed of sound and higher acoustical attenuation than in water and human tissue were found. All materials can be cast into arbitrary shapes and are suitable for tissue-mimicking phantoms. Due to its lower speed of sound, silicone is generally less suitable than the other presented materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydraulic hydrogel actuators and robots optically and sonically camouflaged in water
Yuk, H., Lin, S., Ma, C., Takaffoli, M., Fang, N. X., & Zhao, X. (2017) · Nature Communications · doi:10.1038/ncomms14230 · Cited by 988
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Deep-tissue focal fluorescence imaging with digitally time-reversed ultrasound-encoded light
Wang, Y. M., Judkewitz, B., DiMarzio, C. A., & Yang, C. (2012) · Nature Communications · doi:10.1038/ncomms1925 · Cited by 358
Materials used to simulate physical properties of human skin
Dąbrowska, A. K., Rotaru, G. ‐., Derler, S., Spano, F., Camenzind, M., Annaheim, S., Stämpfli, R., Schmid, M., & Rossi, R. M. (2016) · Skin Research and Technology · doi:10.1111/srt.12235 · Cited by 259
Kandadai, M. A., Raymond, J. L., & Shaw, G. J. (2012) · Materials Science and Engineering: C · doi:10.1016/j.msec.2012.07.024 · Cited by 102
Metadata
- Authors
- Zell, K., Sperl, J. I., Vogel, M. W., Niessner, R., & Haisch, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-10-01
- Volume
- 52
- Issue
- 20
- Pages
- N475-N484
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2030360632
- Cited by
- 336
- References
- 0
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustical properties of selected tissue phantom materials for ultrasound imaging. https://app.cochat.ai/papers/10.1088/0031-9155/52/20/n02
- The paper
- Zell, K., Sperl, J. I., Vogel, M. W., Niessner, R., & Haisch, C. (2007). Acoustical properties of selected tissue phantom materials for ultrasound imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/52/20/n02
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.