Cited by 142Medical Imaging Techniques and ApplicationsCardiac Imaging and DiagnosticsAdvanced X-ray and CT Imaging

Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET

Rapisarda, E, Bettinardi, V, Thielemans, K, Gilardi, M C·2010·Physics in Medicine and Biology

Abstract

The interest in positron emission tomography (PET) and particularly in hybrid integrated PET/CT systems has significantly increased in the last few years due to the improved quality of the obtained images. Nevertheless, one of the most important limits of the PET imaging technique is still its poor spatial resolution due to several physical factors originating both at the emission (e.g. positron range, photon non-collinearity) and at detection levels (e.g. scatter inside the scintillating crystals, finite dimensions of the crystals and depth of interaction). To improve the spatial resolution of the images, a possible way consists of measuring the point spread function (PSF) of the system and then accounting for it inside the reconstruction algorithm. In this work, the system response of the GE Discovery STE operating in 3D mode has been characterized by acquiring (22)Na point sources in different positions of the scanner field of view. An image-based model of the PSF was then obtained by fitting asymmetric two-dimensional Gaussians on the (22)Na images reconstructed with small pixel sizes. The PSF was then incorporated, at the image level, in a three-dimensional ordered subset maximum likelihood expectation maximization (OS-MLEM) reconstruction algorithm. A qualitative and quantitative validation of the algorithm accounting for the PSF has been performed on phantom and clinical data, showing improved spatial resolution, higher contrast and lower noise compared with the corres…

Integrity signals

Registry

Crossref · 10.1088/0031-9155/55/14/012

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PSF reconstruction improves reconstructed spatial resolution and increases lesion SUV but can lead to overestimation of true activity due to Gibbs' artifacts.

    “This improves reconstructed spatial resolution [97,98] and increases lesion SUV [99,100] but can lead to overestimation of the true activity due to so-called Gibbs’ artifacts [92,93].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [98]

  • Discrepancies about PSF may stem from the ability of PSF to increase lesion contrast recovery being most prominent at the periphery of the transaxial FOV and in small, high-contrast lesions such as pulmonary nodules.

    “These discrepancies may stem from the fact that the ability of PSF to increase lesion CR is most prominent at the periphery of the transaxial FOV [98,166,167] and in small, high-contrast lesions [95], such as pulmonary nodules.”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [98]

The citation lists haven’t been fetched yet

References 24 · Cited by 142

Authors
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C.
Affiliations
  • IRCCS Ospedale San Raffaele (IT)
  • Hammersmith Hospital (GB)
  • University of Milano-Bicocca (IT)
Venue
Physics in Medicine and Biology
Published
2010-07-05
Volume
55
Issue
14
Pages
4131-4151
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2032558388
Cited by
142
References
24
Citations by year
2026: 2 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 4 · 2021: 10 · 2020: 8 · 2019: 8 · 2018: 7 · 2017: 11 · 2016: 9 · 2015: 15 · 2014: 15 · 2013: 10 · 2012: 13
FWCI
9.37
Type
journal article
Language
en
Open access
closed
Locations
  • Physics in Medicine and Biology (publishedVersion)
  • PubMed (publishedVersion)
  • BOA (University of Milano-Bicocca) (submittedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • VUBIR (Vrije Universiteit Brussel) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
Keywords
point spread function, PET image reconstruction, 3D-OSEM, spatial resolution, PET/CT, depth of interaction
MeSH terms
Abdomen, Algorithms, Brain, Humans, Models, Biological, Sodium Radioisotopes, Tomography, X-Ray Computed, Normal Distribution, Likelihood Functions, Phantoms, Imaging, Fluorodeoxyglucose F18, Imaging, Three-Dimensional, Positron-Emission Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review