The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Polymer gel dosimetry
Open accessAbstract
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Relaxation Effects in Nuclear Magnetic Resonance Absorption
Bloembergen, N., Purcell, E. M., & Pound, R. V. (1948) · Physical Review · doi:10.1103/physrev.73.679 · Cited by 6,528
A technique for the quantitative evaluation of dose distributions
Low, D. A., Harms, W. B., Mutic, S., & Purdy, J. A. (1998) · Medical Physics · doi:10.1118/1.598248 · Cited by 2,880
Introduction to radiation chemistry
(1991) · Environment International · doi:10.1016/0160-4120(91)90298-5 · Cited by 1,735
Computed Tomography: Principles, Design, Artifacts, and Recent Advances
Hsieh, J. (2015) · doi:10.1117/3.2197756 · Cited by 1,400
Radiation chemistry of polymeric systems
CHAPIRO, A. (1962) · Interscience eBooks · Cited by 1,167
Nuclear Spin Relaxation in Ellipsoids Undergoing Rotational Brownian Motion
Woessner, D. E. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1701390 · Cited by 904
Radiation Chemistry of Polymeric Systems
Calkins, V. P. (1963) · Nuclear Science and Engineering · doi:10.13182/nse63-a26492 · Cited by 739
The science and technology of gelatin
Veis, A. (1978) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(78)90323-5 · Cited by 703
Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging
Gore, J. C., & Kang, Y. S. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/10/002 · Cited by 518
Cited by
Biomedical applications of boronic acid polymers
Cambre, J. N., & Sumerlin, B. S. (2011) · Polymer · doi:10.1016/j.polymer.2011.07.057 · Cited by 435
Nanomaterials Based on Functional Polymers for Sensitizing Cancer Radiotherapy
Lin, J., Yin, M., Liu, X., Meng, F., & Luo, L. (2022) · Macromolecular Rapid Communications · doi:10.1002/marc.202200194 · Cited by 18
Metadata
- Authors
- Baldock, C., De Deene, Y., Doran, S., Ibbott, G., Jirasek, A., Lepage, M., McAuley, K. B., Oldham, M., & Schreiner, L. J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-02-11
- Volume
- 55
- Issue
- 5
- Pages
- R1-R63
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W122927108
- Cited by
- 881
- References
- 36
- FWCI
- 51.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polymer gel dosimetry. https://app.cochat.ai/papers/10.1088/0031-9155/55/5/r01
- The paper
- Baldock, C., De Deene, Y., Doran, S., Ibbott, G., Jirasek, A., Lepage, M., McAuley, K. B., Oldham, M., & Schreiner, L. J. (2010). Polymer gel dosimetry. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/55/5/r01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.