The refractive index of human hemoglobin in the visible range
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l(-1). This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l(-1). The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Refractive Index of Water and Its Dependence on Wavelength, Temperature, and Density
Thormählen, I., Straub, J., & Grigull, U. (1985) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555743 · Cited by 367
Determination of Hemoglobin and Its Derivatives
(1966) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(08)60414-x · Cited by 349
Disorders of Hemoglobin: Genetics, Pathophysiology, and Clinical Management
Steinberg, M. H., Forget, B. G., Higgs, D. R., & Weatherall, D. J. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596582 · Cited by 273
Oxygen Saturation-Dependent Absorption and Scattering of Blood
Faber, D. J., Aalders, M. C. G., Mik, E. G., Hooper, B. A., van Gemert, M. J. C., & van Leeuwen, T. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.028102 · Cited by 264 · cited 3×
“Recently, the refractive index within the visible and near-infrared range has been found by applying Kramers–Kronig relations (Faber et al 2004) and by simultaneous measurements of both specular reflection and light absorption spectra (Friebel and Meinke 2005, 2006).”
BackgroundMethodInfluentialRappaz, B., Barbul, A., Emery, Y., Korenstein, R., Depeursinge, C. D., Magistretti, P. J., & Marquet, P. P. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20605 · Cited by 217 · cited 1×
“In 1957, Barer (1957) determined the real part of the refractive index of hemoglobin at a single wavelength of 589 nm, and his result has been actively used ever since, see e.g. Friebel and Meinke (2005, 2006), Rappaz et al (2008).”
BackgroundRefractive index measurement for biomaterial samples by total internal reflection
Jin, Y., Chen, J., Xu, L., & Wang, P. N. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/20/n02 · Cited by 132 · cited 1×
“For the hemoglobin concentration of 64.5 g l−1 at 25 ◦C, Jin et al (2006) reported the value of the refractive index of 1.335 at 632.8 nm, whereas our value is about 1.343 at the same wavelength.”
BackgroundInfluentialFriebel, M. F., & Meinke, M. C. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2138027 · Cited by 110 · cited 4×
“Recently, the refractive index within the visible and near-infrared range has been found by applying Kramers–Kronig relations (Faber et al 2004) and by simultaneous measurements of both specular reflection and light absorption spectra (Friebel and Meinke 2005, 2006).”
BackgroundMethodInfluentialLaboratory Methods for Diagnosis and Evaluation of Hemoglobin Disorders
Steinberg, M. H., Fabry, M. E., & Old, J. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596582.038 · Cited by 13
Cited by
Kandilian, R., Lee, E., & Pilon, L. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2013.03.058 · Cited by 88
Spectral optical properties of selected photosynthetic microalgae producing biofuels
Lee, E., Heng, R.-L., & Pilon, L. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2012.08.012 · Cited by 74
Light transfer in agar immobilized microalgae cell cultures
Kandilian, R., Jesus, B., Legrand, J., Pilon, L., & Pruvost, J. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.04.027 · Cited by 20
Metadata
- Authors
- Zhernovaya, O., Sydoruk, O., Tuchin, V, & Douplik, A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-06-15
- Volume
- 56
- Issue
- 13
- Pages
- 4013-4021
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2123277610
- Cited by
- 211
- References
- 9
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The refractive index of human hemoglobin in the visible range. https://app.cochat.ai/papers/10.1088/0031-9155/56/13/017
- The paper
- Zhernovaya, O., Sydoruk, O., Tuchin, V, & Douplik, A. (2011). The refractive index of human hemoglobin in the visible range. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/13/017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.