Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, of 20 patients who underwent therapy for large space-occupying tumors. Performance variability was assessed through three geometric measures: volume, Dice similarity coefficient, and Euclidean distance. In addition, two simulated ground truth segmentations were calculated via the simultaneous truth and performance level estimation algorithm and a novel application of probability maps. The experts and automatic system were found to generate structures of similar volume, though the experts exhibited higher variation with respect to tubular structures. No difference was found between the mean Dice similarity coefficient (DSC) of the automatic and expert delineations as a group at a 5% significance level over all cases and organs. The larger structures of the brainstem and eyes exhibited mean DSC of approximately 0.8-0.9, whereas the tubular chiasm and nerves were lower, approximately 0.4-0.5. Similarly low DSCs have been reported previously without the context of several experts and patient volumes. This study, however, provides evidence that experts are similarly challenged. The average maximum distances (maximum inside, maximum outside) from a simulated ground truth ranged from (-4.3, +5.4) mm for the automatic system to (-3.9, +7.5) mm for the experts considered as a group. Over all the structures in a rank of true positive rates at a 2 mm threshold from the simulated ground truth, the automatic system ranked second of the nine raters. This work underscores the need for large scale studies utilizing statistically robust numbers of patients and experts in evaluating quality of automatic algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bootstrap Methods and their Application
Davison, A. C., & Hinkley, D. V. (1997) · doi:10.1017/cbo9780511802843 · Cited by 7,350
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 3×
“This algorithm uses normalized mutual information (Studholme et al 1999) as the similarity measure and models the deformation field that registers the two images as a linear combination of radial basis functions (Wu 1995) with finite support. Both the forward and the backward transformations are computed simultaneousl…”
MethodInfluentialGeneralized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776 · cited 1×
“While these yield a good sense of volume overlap of two segmentations, they provide little in terms of the scale of mismatch (Crum et al 2006).”
Background
Cited by
A survey of MRI-based medical image analysis for brain tumor studies
Bauer, S., Wiest, R., Nolte, L.-P., & Reyes, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/r97 · Cited by 1,036
Segmentation of organs‐at‐risks in head and neck CT images using convolutional neural networks
Ibragimov, B., & Xing, L. (2017) · Medical Physics · doi:10.1002/mp.12045 · Cited by 502
3D fully convolutional networks for subcortical segmentation in MRI: A large-scale study
Dolz, J., Desrosiers, C., & Ben Ayed, I. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.039 · Cited by 414
Vision 20/20: Perspectives on automated image segmentation for radiotherapy
Sharp, G., Fritscher, K. D., Pekar, V., Peroni, M., Shusharina, N., Veeraraghavan, H., & Yang, J. (2014) · Medical Physics · doi:10.1118/1.4871620 · Cited by 375
Evaluation of segmentation methods on head and neck CT: Auto‐segmentation challenge 2015
Raudaschl, P. F., Zaffino, P., Sharp, G. C., Spadea, M. F., Chen, A., Dawant, B. M., Albrecht, T., Gass, T., Langguth, C., Lüthi, M., et al. (2017) · Medical Physics · doi:10.1002/mp.12197 · Cited by 259
Self-citation
Metadata
- Authors
- Deeley, M. A., Chen, A., Datteri, R., Noble, J. H., Cmelak, A. J., Donnelly, E. F., Malcolm, A. W., Moretti, L., Jaboin, J., Niermann, K., Yang, E. S., Yu, D. S., Yei, F., Koyama, T., Ding, G. X., & Dawant, B. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-07-01
- Volume
- 56
- Issue
- 14
- Pages
- 4557-4577
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2029119154
- Cited by
- 143
- References
- 3
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study. https://app.cochat.ai/papers/10.1088/0031-9155/56/14/021
- The paper
- Deeley, M. A., Chen, A., Datteri, R., Noble, J. H., Cmelak, A. J., Donnelly, E. F., Malcolm, A. W., Moretti, L., Jaboin, J., Niermann, K., Yang, E. S., Yu, D. S., Yei, F., Koyama, T., Ding, G. X., & Dawant, B. M. (2011). Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/14/021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.