Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems (TPSs) can only rely on fast-performing analytical algorithms. However, the rapidly emerging though more computationally intensive Monte Carlo (MC) methods can be employed to complement analytical TPS, e.g., via accurate calculations of the input beam-model data, together with a considerable reduction of the measuring time. Here we present the work done for the application of the FLUKA MC code to support several aspects of scanned ion beam delivery and treatment planning at the Heidelberg Ion Beam Therapy Center (HIT). Emphasis is given to the generation of the accelerator library and of experimentally validated TPS input basic data which are now in clinical use for proton and carbon ion therapy. Additionally, MC dose calculations of planned treatments in water are shown to represent a valuable tool for supporting treatment plan verification in comparison to dosimetric measurements. This paper can thus provide useful information and guidelines for the start-up and clinical operation of forthcoming ion beam therapy facilities similar to HIT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
The FLUKA code: description and benchmarking
Battistoni, G., Cerutti, F., Fassò, A., Ferrari, A., Muraro, S., Ranft, J., Roesler, S., & Sala, P. R. (2007) · AIP Conference Proceedings · doi:10.1063/1.2720455 · Cited by 1,308
Magnetic scanning system for heavy ion therapy
Haberer, T., Becher, W., Schardt, D., & Kraft, G. (1993) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(93)91335-k · Cited by 730
Self-citationComments on ICRU Report No. 49: Stopping Powers and Ranges for Protons and Alpha Particles
Ziegler, J. F. (1999) · Radiation Research · doi:10.2307/3580097 · Cited by 616
Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization
Krämer, M., Jäkel, O., Haberer, T., Kraft, G., Schardt, D., & Weber, U. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/313 · Cited by 505
Self-citationComputation of cell survival in heavy ion beams for therapy
Scholz, M., Kellerer, A. M., Kraft-Weyrather, W., & Kraft, G. (1997) · Radiation and Environmental Biophysics · doi:10.1007/s004110050055 · Cited by 464
Krämer, M., & Scholz, M. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/314 · Cited by 453 · cited 17×
“In the GSI pilot project, a library of 252 energies (originally at least partially motivated by system limitations to 1 byte value), 7 foci and 15 intensity steps was clinically used for carbon ions.”
MethodInfluentialA Generalized Formulation of Dual Radiation Action1
Kellerer, A. M., & Rossi, H. H. (2012) · Radiation Research · doi:10.1667/rrav17.1 · Cited by 361
Cited by
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Development of the open-source dose calculation and optimization toolkit matRad
Wieser, H.-P., Cisternas, E., Wahl, N., Ulrich, S., Stadler, A., Mescher, H., Müller, L.-R., Klinge, T., Gabrys, H., Burigo, L., et al. (2017) · Medical Physics · doi:10.1002/mp.12251 · Cited by 325
Self-citationThe FLUKA Code: An Accurate Simulation Tool for Particle Therapy
Battistoni, G., Bauer, J., Boehlen, T. T., Cerutti, F., Chin, M. P. W., Dos Santos Augusto, R., Ferrari, A., Ortega, P. G., Kozłowska, W., Magro, G., et al. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00116 · Cited by 272
Self-citationCarante, M. P., Aricò, G., Ferrari, A., Kozlowska, W., Mairani, A., & Ballarini, F. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab490f · Cited by 23
Self-citation
Metadata
- Authors
- Parodi, K., Mairani, A., Brons, S., Hasch, B. G., Sommerer, F., Naumann, J., Jäkel, O., Haberer, T., & Debus, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-05-23
- Volume
- 57
- Issue
- 12
- Pages
- 3759-3784
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2077172984
- Cited by
- 221
- References
- 26
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.