Iterative image reconstruction algorithms for optoacoustic tomography (OAT), also known as photoacoustic tomography, have the ability to improve image quality over analytic algorithms due to their ability to incorporate accurate models of the imaging physics, instrument response and measurement noise. However, to date, there have been few reported attempts to employ advanced iterative image reconstruction algorithms for improving image quality in three-dimensional (3D) OAT. In this work, we implement and investigate two iterative image reconstruction methods for use with a 3D OAT small animal imager: namely a penalized least-squares (PLS) method employing a quadratic smoothness penalty and a PLS method employing a total variation norm penalty. The reconstruction algorithms employ accurate models of the ultrasonic transducer impulse responses. Experimental data sets are employed to compare the performances of the iterative reconstruction algorithms to that of a 3D filtered backprojection (FBP) algorithm. By the use of quantitative measures of image quality, we demonstrate that the iterative reconstruction algorithms can mitigate image artifacts and preserve spatial resolution more effectively than FBP algorithms. These features suggest that the use of advanced image reconstruction algorithms can improve the effectiveness of 3D OAT while reducing the amount of data required for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beck, A., & Teboulle, M. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028250 · Cited by 2,004
OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images
Rosset, A., Spadola, L., & Ratib, O. (2004) · Journal of Digital Imaging · doi:10.1007/s10278-004-1014-6 · Cited by 1,767
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Biomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Tutorial on Photoacoustic Microscopy and Computed Tomography
Wang, L. V. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.913398 · Cited by 607 · cited 1×
“Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging imaging modality that has great potential for a wide range of biomedical imaging applications (Oraevsky & Karabutov, 2003; Wang, 2008; Kruger, et al., 1999; Cox, et al., 2006).”
BackgroundPan, X., Sidky, E. Y., & Vannier, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123009 · Cited by 572
Determining a Function from Its Mean Values Over a Family of Spheres
Finch, D., & Patch, S. K. (2004) · SIAM Journal on Mathematical Analysis · doi:10.1137/s0036141002417814 · Cited by 410
Emission Tomography: The Fundamentals of PET and SPECT
Wernick, M. N., & Aarsvold, J. N. (2004) · Cited by 353
The Application of Compressed Sensing for Photo-Acoustic Tomography
Provost, J., & Lesage, F. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2007825 · Cited by 338
Cited by
PHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
Fully Dense UNet for 2-D Sparse Photoacoustic Tomography Artifact Removal
Guan, S., Khan, A. A., Sikdar, S., & Chitnis, P. V. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2912935 · Cited by 538
The emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Deep learning for photoacoustic tomography from sparse data
Antholzer, S., Haltmeier, M., & Schwab, J. (2019) · Inverse Problems in Science and Engineering · doi:10.1080/17415977.2018.1518444 · Cited by 301
Huang, C., Wang, K., Nie, L., Wang, L. V., & Anastasio, M. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2254496 · Cited by 276
Self-citationSmall-Animal Whole-Body Photoacoustic Tomography: A Review
Xia, J., & Wang, L. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283507 · Cited by 242
“of these comprehensive imaging models, more accurate images have been reconstructed using iterative image reconstruction algorithms [34], [36].”
BackgroundMethodAcoustic Inversion in Optoacoustic Tomography: A Review
Rosenthal, A., Ntziachristos, V., & Razansky, D. (2014) · Current Medical Imaging Reviews · doi:10.2174/15734056113096660006 · Cited by 236
“Many regularization techniques have been demonstrated for optoacoustic tomography, including Tikhonov regularization [113, 115], singular value decomposition (SVD) [115], multi-scale techniques [115, 116], limited-iteration LSQR [117], and total-variation (TV) regularization [118].”
Optoacoustic mesoscopy for biomedicine
Omar, M., Aguirre, J., & Ntziachristos, V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0377-4 · Cited by 204
Wang, K., Matthews, T., Anis, F., Li, C., Duric, N., & Anastasio, M. (2015) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.006788 · Cited by 165
“The use of this parameter can be avoided when advanced optimization al gorithms are employed [52], [53].”
Self-citation
Metadata
- Authors
- Wang, K., Su, R., Oraevsky, A. A., & Anastasio, M. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-08-03
- Volume
- 57
- Issue
- 17
- Pages
- 5399-5423
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2068358021
- Cited by
- 191
- References
- 29
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.