The DOI matches its Crossref record; the references it cites are not checked yet.
Low LET protons focused to submicrometer shows enhanced radiobiological effectiveness
Abstract
This study shows that enhanced radiobiological effectiveness (RBE) values can be generated focusing low linear energy transfer (LET) radiation and thus changing the microdose distribution. 20 MeV protons (LET = 2.65 keV µm(-1)) are focused to submicrometer diameter at the ion microprobe superconducting nanoprobe for applied nuclear (Kern) physics experiments of the Munich tandem accelerator. The RBE values, as determined by measuring micronuclei (RBE(MN) = 1.48 ± 0.07) and dicentrics (RBE(D) = 1.92 ± 0.15), in human-hamster hybrid (A(L)) cells are significantly higher when 117 protons were focused to a submicrometer irradiation field within a 5.4 × 5.4 µm(2) matrix compared to quasi homogeneous in a 1 × 1 µm(2) matrix applied protons (RBE(MN) = 1.28 ± 0.07; RBE(D) = 1.41 ± 0.14) at the same average dose of 1.7 Gy. The RBE values are normalized to standard 70 kV (dicentrics) or 200 kV (micronuclei) x-ray irradiation. The 117 protons applied per point deposit the same amount of energy like a (12)C ion with 55 MeV total energy (4.48 MeV u(-1)). The enhancements are about half of that obtained for (12)C ions (RBE(MN) = 2.20 ± 0.06 and RBE(D) = 3.21 ± 0.10) and they are attributed to intertrack interactions of the induced damages. The measured RBE values show differences from predictions of the local effect model (LEM III) that is used to calculate RBE values for irradiation plans to treat tumors with high LET particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Based on novel experiments with sub-micrometre focusing of ion beams, both scales have been implicated in induction of chromosome aberrations and cell killing.
“Indeed, based on novel experiments with sub-micrometre focusing of ion beams, both scales have been implicated in the induction of chromosome aberrations and cell killing6364.”
From Comprehensive track-structure based evaluation of DNA damage by light ions from radiotherapy-relevant energies down to stopping (2017) · cites this paper as [64]
Citations
The citation lists haven’t been fetched yet
References 35 · Cited by 27
Research works printed but not linked: 33
- 10.1016/S0168-583X(01)00549-3 · DOI
- 10.2307/3573230 · DOI
- 10.1016/j.nimb.2005.01.056 · DOI
- 10.1063/1.3699063 · DOI
- 10.1038/nrclinonc.2009.183 · DOI
- 10.1667/RR2063.1 · DOI
- Elsässer T, 2008, New J. Phys., 10, 10.1088/1367-2630/10/7/075005 · DOI
- 10.1016/j.ijrobp.2008.02.037 · DOI
- 10.1093/rpd/ncl521 · DOI
- 10.1667/RR0467.1 · DOI
- 10.1016/j.ijrobp.2010.05.014 · DOI
- Fourkal E, 2011, Phys. Med. Biol., 56, 3123, 10.1088/0031-9155/56/10/015 · DOI
- 10.1016/j.mrfmmm.2011.01.003 · DOI · Paper page
- 10.3109/09553002.2011.611213 · DOI
- 10.1007/s00411-008-0181-0 · DOI
- 10.1007/s00411-003-0222-7 · DOI
- 10.1093/rpd/ncl420 · DOI
- 10.1093/rpd/ncq517 · DOI
- 10.1007/s00066-007-1645-x · DOI
- 10.1016/j.ijrobp.2006.08.045 · DOI
- 10.1007/s00411-009-0234-z · DOI
- 10.1080/09553009514550881 · DOI
- 10.1038/nrc3069 · DOI
- 10.1016/0165-7992(95)00056-9 · DOI
- 10.3109/09553001003734543 · DOI
- 10.1667/RR2465.1 · DOI
- 10.1667/RR1539.1 · DOI
- 10.1016/j.radonc.2010.03.010 · DOI
- 10.1016/0273-1177(95)00784-C · DOI
- 10.1093/rpd/ncl426 · DOI
- 10.1097/PPO.0b013e3181b01922 · DOI
- 10.1063/1.3551623 · DOI
- Yu C K, 1967, J. Natl Cancer Inst., 39, 619
Metadata
- Authors
- Schmid, T. E., Greubel, C., Hable, V, Zlobinskaya, O., Michalski, D., Girst, S., Siebenwirth, C., Schmid, E., Molls, M., Multhoff, G., & Dollinger, G.
- Affiliations
- Technical University of Munich (DE)
- Universität der Bundeswehr München (DE)
- Ludwig-Maximilians-Universität München (DE)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-09-07
- Volume
- 57
- Issue
- 19
- Pages
- 5889-5907
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1990970154
- Cited by
- 27
- References
- 35
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2020: 1 · 2019: 3 · 2018: 4 · 2017: 7 · 2016: 1 · 2015: 5 · 2014: 2
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
- Site cant be reached (submittedVersion)
- Funders
- Deutsche Forschungsgemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Ion-surface interactions and analysis
- Keywords
- radiobiological effectiveness, proton beam focusing, micronuclei, dicentric chromosomes, ion microprobe, local effect model, carbon ion radiotherapy
- MeSH terms
- Animals, Cricetulus, Cricetinae, Histones, Humans, Relative Biological Effectiveness, CHO Cells, Linear Energy Transfer, Proton Therapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review