Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The x-ray exposure to patients has become a major concern in computed tomography (CT) and minimizing the radiation exposure has been one of the major efforts in the CT field. Due to plenty high-attenuation tissues in the human chest, under low-dose scan protocols, thoracic low-dose CT (LDCT) images tend to be severely degraded by excessive mottled noise and non-stationary streak artifacts. Their removal is rather a challenging task because the streak artifacts with directional prominence are often hard to discriminate from the attenuation information of normal tissues. This paper describes a two-step processing scheme called 'artifact suppressed large-scale nonlocal means' for suppressing both noise and artifacts in thoracic LDCT images. Specific scale and direction properties were exploited to discriminate the noise and artifacts from image structures. Parallel implementation has been introduced to speed up the whole processing by more than 100 times. Phantom and patient CT images were both acquired for evaluation purpose. Comparative qualitative and quantitative analyses were both performed that allows conclusion on the efficacy of our method in improving thoracic LDCT data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Non-Local Algorithm for Image Denoising
Buades, A., Coll, B., & Morel, J.-M. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.38 · Cited by 7,616 · cited 2×
“In [20], a weighted intensity averaging over large-scale neighborhoods (WIA-LN) was proposed for processing abdominal LDCT images, which can be deemed as a large-scale nonlocal means (LNLM) [21-23].”
Method
Cited by
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network
Yi, X., & Babyn, P. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0056-0 · Cited by 343
Artifact Suppressed Dictionary Learning for Low-Dose CT Image Processing
Chen, Y., Shi, L., Feng, Q., Yang, J., Shu, H., Luo, L., Coatrieux, J.-L., & Chen, W. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2336860 · Cited by 315
Self-citationImproving abdomen tumor low-dose CT images using a fast dictionary learning based processing
Chen, Y., Yin, X., Shi, L., Shu, H., Luo, L., Coatrieux, J.-L., & Toumoulin, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5803 · Cited by 223
“This LNLM method was further combined with a multiscale directional diffusion to suppress the streak artifacts in thoracic CT images [24].”
MethodSelf-citationConvolutional auto-encoder for image denoising of ultra-low-dose CT
Nishio, M., Nagashima, C., Hirabayashi, S., Ohnishi, A., Sasaki, K., Sagawa, T., Hamada, M., & Yamashita, T. (2017) · Heliyon · doi:10.1016/j.heliyon.2017.e00393 · Cited by 106
“Because images obtained by LDCT or ULDCT are severely affected by noise (e.g., streak artifact) and differentiation between normal/abnormal findings on the noisy CT images is difficult, image-processing techniques have been utilized to improve image quality of LDCT or ULDCT [4, 5, 6, 7, 8, 9, 10].”
Method
Metadata
- Authors
- Chen, Y., Yang, Z., Hu, Y., Yang, G., Zhu, Y., Li, Y., luo, L., Chen, W., & Toumoulin, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-04-13
- Volume
- 57
- Issue
- 9
- Pages
- 2667-2688
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2042743306
- Cited by
- 143
- References
- 2
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means. https://app.cochat.ai/papers/10.1088/0031-9155/57/9/2667
- The paper
- Chen, Y., Yang, Z., Hu, Y., Yang, G., Zhu, Y., Li, Y., luo, L., Chen, W., & Toumoulin, C. (2012). Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/57/9/2667
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.