A compact, high performance atomic magnetometer for biomedical applications
Open accessAbstract
We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) magnetometers. We present side-by-side comparisons between our AM and a SQUID magnetometer, and show that equally high quality magnetoencephalography and magnetocardiography recordings can be obtained using our AM.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
OPMs are a non-cryogenic alternative to SQUID-based MCG systems.
“Another non-cryogenic alternative to SQUID-based MCG systems is the use of OPMs (269).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [269]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 21 · Cited by 322
Research works printed but not linked: 3
- [11]Wyllie R Kauer M Smetana GS Wakai RT Walker TG Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array Phys. Med. Biol 5 2012 57 9 2619 2632 22504066 PMC3368342
- [14]Preusser J Knappe S Gerginov V Kitching J A microfabricated photonic magnetometer 2009 1 European Conference on Lasers and Electro-Optics 2009 and the European Quantum Electronics Conference. CLEO Europe - EQEC 2009
- [15]Sander TH Preusser J Mhaskar R Kitching J Trahms L Knappe S Magnetoencephalography with a chip-scale atomic magnetometer Biomed. Opt. Express 4 2012 3 5 981 990 22567591 PMC3342203
- Authors
- Shah, V. K., & Wakai, R. T.
- Affiliations
- QuSpin (United States) (US)
- University of Wisconsin–Madison (US)
- Corresponding author
- Shah, Vishal K
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-11-07
- Volume
- 58
- Issue
- 22
- Pages
- 8153-8161
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC3971838
- OpenAlex
- W2010111760
- Cited by
- 322
- References
- 21
- Citations by year
- 2026: 28 · 2025: 31 · 2024: 32 · 2023: 41 · 2022: 57 · 2021: 26 · 2020: 29 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 18 · 2015: 10 · 2014: 8
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Heart, Lung, and Blood Institute (R01HL063174, R43HL114182)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R43HD074495, R44HD080045)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- atomic magnetometer, room-temperature magnetometry, low-cost optical components, magnetic field resolution, magnetoencephalography, magnetocardiography, compact sensor design
- MeSH terms
- Equipment Design, Humans, Magnetoencephalography, Magnetocardiography, Magnetometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review