Ferromagnetic resonance of ultrathin metallic layers
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The contribution that the technique of ferromagnetic resonance (FMR) has made to the understanding of the magnetic behaviour of ultrathin single films is reviewed. Experimental methods to measure FMR in situ in ultrahigh vacuum are presented. The temperature dependence of the magnetization, of the magnetic relaxation rate in the vicinity of the Curie temperature, and of the second- and fourth-order magnetic anisotropy energy (MAE) constants can be measured by FMR in situ for magnetic monolayers. Using the cases of Ni/Cu(001) and Gd/W(110) as examples, the role of the MAE for the quantitative description of temperature- and thickness-dependent reorientation transitions of the magnetization is discussed. Initial results for the anisotropy of the g -factor which is related to the anisotropy of the orbital moment (and the MAE) are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical properties of thin films
Nix, W. D. (1989) · Metallurgical Transactions A · doi:10.1007/bf02666659 · Cited by 2,546
Experiments on simple magnetic model systems
de Jongh, L. J., & Miedema, A. R. (1974) · Advances in Physics · doi:10.1080/00018739700101558 · Cited by 2,170
Poole, C. P., & Rogers, R. N. (1968) · American Journal of Physics · doi:10.1119/1.1975130 · Cited by 1,678
Magnetic anisotropy in metallic multilayers
Johnson, M. T., Bloemen, P. J. H., den Broeder, F. J. A., & de Vries, J. J. (1996) · Reports on Progress in Physics · doi:10.1088/0034-4885/59/11/002 · Cited by 1,292
First-principles calculation of the magnetocrystalline anisotropy energy of iron, cobalt, and nickel
Daalderop, G. H. O., Kelly, P. J., & Schuurmans, M. F. H. (1990) · Physical Review B · doi:10.1103/physrevb.41.11919 · Cited by 685
Mezey, L. Z., & Giber, J. (1982) · Japanese Journal of Applied Physics · doi:10.1143/jjap.21.1569 · Cited by 655
Surface, interface, and thin-film magnetism
Falicov, L. M., Pierce, D. T., Bader, S. D., Gronsky, R., Hathaway, K. B., Hopster, H. J., Lambeth, D. N., Parkin, S. S. P., Prinz, G., Salamon, M., et al. (1990) · Journal of Materials Research · doi:10.1557/jmr.1990.1299 · Cited by 464
Huang, F., Kief, M. T., Mankey, G. J., & Willis, R. F. (1994) · Physical Review B · doi:10.1103/physrevb.49.3962 · Cited by 459
Magnetization and Electrical Resistivity of Gadolinium Single Crystals
Nigh, H. E., Legvold, S., & Spedding, F. H. (1963) · Physical Review · doi:10.1103/physrev.132.1092 · Cited by 401
Nonequilibrium Magnetization Dynamics of Nickel
Hohlfeld, J., Matthias, E., Knorren, R., & Bennemann, K. H. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.4861 · Cited by 383
Cited by
Magnetic Nanoparticles: Synthesis, Protection, Functionalization, and Application
Lu, A., Salabas, E. L., & Schüth, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200602866 · Cited by 6,777
Bedanta, S., & Kleemann, W. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/1/013001 · Cited by 1,011
Skomski, R. (2003) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/15/20/202 · Cited by 935
Perpendicular magnetic anisotropy at transition metal/oxide interfaces and applications
Dieny, B., & Chshiev, M. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.025008 · Cited by 777
Probing condensed matter physics with magnetometry based on nitrogen-vacancy centres in diamond
Casola, F., van der Sar, T., & Yacoby, A. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.88 · Cited by 635
Magnetism in ultrathin film structures
Vaz, C. A. F., Bland, J. A. C., & Lauhoff, G. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/5/056501 · Cited by 592
Scaling of Spin Hall Angle in 3d, 4d, and 5d Metals from Y 3 Fe 5 O 12 /Metal Spin Pumping
Wang, H. L., Du, C. H., Pu, Y., Adur, R., Hammel, P. C., & Yang, F. Y. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.197201 · Cited by 557
All-Optical Probe of Coherent Spin Waves
van Kampen, M., Jozsa, C., Kohlhepp, J. T., LeClair, P., Lagae, L., de Jonge, W. J. M., & Koopmans, B. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.227201 · Cited by 533
X-ray magnetic circular dichroism—A versatile tool to study magnetism
van der Laan, G., & Figueroa, A. I. (2014) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2014.03.018 · Cited by 405
Antiferromagnonic Spin Transport fromY3Fe5O12into NiO
Wang, H., Du, C., Hammel, P. C., & Yang, F. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.097202 · Cited by 350
Micro-focused Brillouin light scattering: imaging spin waves at the nanoscale
Sebastian, T., Schultheiss, K., Obry, B., Hillebrands, B., & Schultheiss, H. (2015) · Frontiers in Physics · doi:10.3389/fphy.2015.00035 · Cited by 325
Magnetische Nanopartikel: Synthese, Stabilisierung, Funktionalisierung und Anwendung
Lu, A., Salabas, E. L., & Schüth, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200602866 · Cited by 266
The magnetic anisotropy and spin reorientation of nanostructures and nanoscale films
Sander, D. (2004) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/16/20/r01 · Cited by 197
“A famous example is the out-of-plane easy magnetization direction over an extended thickness range from 10–50 atomic layers Ni on Cu(001), which is ascribed to the epitaxial strain of the Ni film [25, 58, 59].”
BackgroundConstrained Monte Carlo method and calculation of the temperature dependence of magnetic anisotropy
Asselin, P., Evans, R. F. L., Barker, J., Chantrell, R. W., Yanes, R., Chubykalo-Fesenko, O., Hinzke, D., & Nowak, U. (2010) · Physical Review B · doi:10.1103/physrevb.82.054415 · Cited by 192
Influence of the Dzyaloshinskii–Moriya interaction on the spin-wave spectra of thin films
Cortés-Ortuño, D., & Landeros, P. (2013) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/25/15/156001 · Cited by 187
Maksymov, I. S., & Kostylev, M. (2015) · Physica E: Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2014.12.027 · Cited by 181
A review of high magnetic moment thin films for microscale and nanotechnology applications
Scheunert, G., Heinonen, O., Hardeman, R., Lapicki, A., Gubbins, M., & Bowman, R. M. (2016) · Applied Physics Reviews · doi:10.1063/1.4941311 · Cited by 169
Physical properties of elongated inorganic nanoparticles
Krahne, R., Morello, G., Figuerola, A., George, C., Deka, S., & Manna, L. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.01.001 · Cited by 161
Metadata
- Authors
- Farle, M.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 1998-07-01
- Volume
- 61
- Issue
- 7
- Pages
- 755-826
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2057517447
- Cited by
- 919
- References
- 24
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.