The DOI matches its Crossref record.
Electron energy-loss spectroscopy in the TEM
Open accessAbstract
Electron energy-loss spectroscopy (EELS) is an analytical technique that measures the change in kinetic energy of electrons after they have interacted with a specimen.When carried out in a modern transmission electron microscope, EELS is capable of giving structural and chemical information about a solid, with a spatial resolution down to the atomic level in favourable cases.The energy resolution is typically 1 eV but can approach 0.1 eV if an electron-beam monochromator is used.This review provides an overview of EELS instrumentation and of the physics involved in the scattering of kilovolt electrons in solids.Features of the energy-loss spectrum are discussed, including plasmon peaks, inner-shell ionization edges and fine structure related to the electronic densities of states.Examples are given of the use of EELS for the measurement of local properties, including specimen thickness, mechanical and electronic properties (such as bandgap) and chemical composition.Factors that determine the spatial resolution of the analysis are outlined, including radiation damage to the specimen.Comparisons are made with related techniques, particularly x-ray absorption spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cryo-electron microscopy for structural analysis of dynamic biological macromolecules
Murata, K., & Wolf, M. (2018) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.07.020 · Cited by 331
Nanoscale topographical control of capillary assembly of nanoparticles
Flauraud, V., Mastrangeli, M., Bernasconi, G. D., Butet, J., Alexander, D. T. L., Shahrabi, E., Martin, O. J. F., & Brugger, J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2016.179 · Cited by 328
Recent advances in Pt-based octahedral nanocrystals as high performance fuel cell catalysts
Wang, J., Li, B., Yersak, T., Yang, D., Xiao, Q., Zhang, J., & Zhang, C. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta02748b · Cited by 65
Foetisch, A., Filella, M., Watts, B., Vinot, L.-H., & Bigalke, M. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127804 · Cited by 58
Gualtieri, A. F., Andreozzi, G. B., Tomatis, M., & Turci, F. (2019) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2018.07.023 · Cited by 45
Metadata
- Authors
- Egerton, R. F.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2008-12-16
- Volume
- 72
- Issue
- 1
- Pages
- 016502
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W1988510032
- Cited by
- 814
- References
- 0
- FWCI
- 9.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electron energy-loss spectroscopy in the TEM. https://app.cochat.ai/papers/10.1088/0034-4885/72/1/016502
- The paper
- Egerton, R. F. (2009). Electron energy-loss spectroscopy in the TEM. Reports on Progress in Physics. https://doi.org/10.1088/0034-4885/72/1/016502