Dipole modelling of eye activity and its application to the removal of eye artefacts from the EEG and MEG
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The spatio-temporal dipole model approach has been used to identify the difference dipoles arising from changes in the ocular dipoles due to eye movements and blinks. Based on these results a method has been developed to remove eye artefacts from electrical or magnetic data. The method avoids distortions due to the head model by determining the spatial distribution of the signals from the eyes empirically. Using simultaneous modelling of the EEG or MEG activity with dipole sources distributed within the head together with the empirically determined spatial eye components, the eye activity can be estimated and removed from the EEG or MEG. This greatly reduces the distortion to the topography that is a concomitant of previous eye artefact correction methods. The advantages of the method are illustrated using simulated and real electrical data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Source Analysis of the Late Human Auditory Evoked Potentials
Scherg, M., Vajsar, J., & Picton, T. W. (1989) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1989.1.4.336 · Cited by 705
Self-citation(1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1 · Cited by 452
Removal of ocular artifacts from the EEG — A biophysical approach to the EOG
Elbert, T., Lutzenberger, W., Rockstroh, B., & Birbaumer, N. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)91020-x · Cited by 205
Dipole models of eye movements and blinks
Berg, P., & Scherg, M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90154-v · Cited by 200
Self-citationCorrecting ocular artifacts in the EEG: A comparison of several methods
BRUNIA, C. H. M., Möcks, J., & van den Berg-Lenssen, M. M. C. (1989) · Research portal (Tilburg University) · Cited by 86
Magnetic fields produced by the human eye (invited)
Katila, T. E., Maniewski, R., Poutanen, T., Varpula, T., & Karp, P. (1981) · Journal of Applied Physics · doi:10.1063/1.329000 · Cited by 34
Scalp Distribution of Magnetic Fields Generated by Horizontal Eye Movements and Eye Blinks
Oakley, M., Sullivan, G., Roeder, S. B. W., & Flynn, E. R. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_43 · Cited by 2
Berg, P., & Scherg, M. (1990) · Max Planck Institute for Plasma Physics · Cited by 2
Self-citation
Cited by
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
Self-citationA multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696
Self-citation
Metadata
- Authors
- Berg, P., & Scherg, M.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1991-01-01
- Volume
- 12
- Issue
- A
- Pages
- 49-54
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2034330155
- Cited by
- 169
- References
- 8
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.