Cited by 148Thermal properties of materialsGeothermal Energy Systems and ApplicationsHigh-pressure geophysics and materials

The DOI matches its Crossref record.

Thermal conductivities of fused and crystalline quartz

Open access
Ratcliffe, E H·1959·British Journal of Applied Physics

Abstract

The thermal conductivities of fused quartz and of crystalline quartz (heat-flow at 90° to the optic axis) have been measured by steady-state plate methods; the former over the range -150 to 50° C, and the latter at 28° C. The most probable thermal conductivity values of these two materials have been formulated as functions of temperature, having in mind their use as calibration specimens for apparatus measuring the thermal conductivities of rocks, important in the calculation of terrestrial heat-flow. Detailed description is given of apparatus and measurement methods, and the results of other observers are listed and briefly discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0508-3443/10/1/306

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The 3ω method covers a wide range of temperature bridging the gap between low-temperature methods and elaborate means used to reduce radiation errors near room temperature and above.

    “The solid circles in Fig. 7 demonstrate the wide range of temperature covered by the 3ω method bridging the gap between low-temperature methods² and the elaborate means23–25 used to reduce radiation errors near room temperature and above.”

    From Thermal conductivity measurement from 30 to 750 K: the 3ω method (1990) · cites this paper as [23]

    The Present Measurements section (page unavailable) describes a guard heater and insulation that reduced heat losses in measurements near 28°C, supporting the citation’s reference to measures used near room temperature. Our copy does not identify those losses as radiation errors or discuss the 3ω method; the latter is the citing authors’ own comparison, not a finding attributed to Ratcliffe. (LLM, conf=0.80)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 25

  1. Griffiths E, 1923, Proc. Roy. Soc., 104, 71, 10.1098/rspa.1923.0095 · DOI
  2. Kaye G W C, 1926, Proc. Roy. Soc., 113, 335, 10.1098/rspa.1926.0159 · DOI
  3. Lodge O J, 1878, Phil. Mag., 5, 110, 10.1080/14786447808639396 · DOI
  4. Lees C H, Phil. Trans., 183, 481, 10.1098/rsta.1892.0012 · DOI
  5. Lees C H, 1892, Phil. Trans., 191, 399, 10.1098/rsta.1898.0010 · DOI
  6. Tuchschmid A, 1883, Diss. Zurich
  7. Tuchschmid A, 1884, Beiblatter, Ann. Phys. Chem., 8, 490
  8. Weber R, 1895, Arch. Sci. Phys., 33, 590
  9. Eucken A, 1911, Ann. Phys. (Leipzig), 34, 185, 10.1002/andp.19113390202 · DOI
  10. Eucken A, 1911, Ver. Deut. Phys., Ges., 13, 829
  11. Barratt T, 1914, Proc. Phys. Soc. (London), 27, 81, 10.1088/1478-7814/27/1/306 · DOI
  12. 10.1103/PhysRev.31.119 · DOI
  13. Ito S, 1929, Mazda Res. Rep., 4, 188
  14. Birch F, 1940, Amer. J. Sci., 238, 529, 10.2475/ajs.238.8.529 · DOI · Paper page
  15. Birch F, 1940, Amer. J. Sci., 613, 10.2475/ajs.238.9.613 · DOI
  16. Bullard E C, 1939, Proc. Roy. Soc., 173, 474, 10.1098/rspa.1939.0159 · DOI
  17. Benfield A E, 1939, Proc. Roy. Soc., 173, 428, 10.1098/rspa.1939.0157 · DOI
  18. Coster H P, 1947, Roy. Astron. Soc. Geophys. Suppl., 5, 131, 10.1111/j.1365-246X.1947.tb00349.x · DOI
  19. Bullard E C, 1951, Roy. Astron. Soc. Geophys. Suppl., 6, 222, 10.1111/j.1365-246X.1951.tb03007.x · DOI
  20. Mossop S C, 1951, J. Chem. Soc. S. Africa, 52, 61
  21. Carte A E, 1954, Proc. Phys. Soc. (London), 67, 664, 10.1088/0370-1301/67/9/302 · DOI
  22. Knapp W J, 1943, J. Amer. Ceram. Soc., 26, 48, 10.1111/j.1151-2916.1943.tb15185.x · DOI
  23. Colosky B P, 1952, Bull. Amer. Ceram. Soc., 31, 465
  24. Gafner G, 1957, Brit. J. Appl. Phys., 8, 393, 10.1088/0508-3443/8/10/302 · DOI
  25. Berman R, 1951, Proc. Roy. Soc., 208, 90, 10.1098/rspa.1951.0146 · DOI

Cited by

Sorted by citations

Metadata

Authors
Ratcliffe, E. H.
Affiliations
National Physical Laboratory (GB)
Corresponding author
Ratcliffe, E H
Venue
British Journal of Applied Physics
Published
1959-01
Volume
10
Issue
1
Pages
22-25
ISSN
0508-3443 (ISSN-L)
OpenAlex
W2087176794
Cited by
148
References
0
Citations by year
2026: 2 · 2025: 6 · 2024: 1 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 5 · 2017: 4 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
FWCI
3.02
Type
journal article
Language
en
Open access
Locations
British Journal of Applied Physics (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Geothermal Energy Systems and Applications
  • Physical Sciences › Earth and Planetary Sciences › Geophysics › High-pressure geophysics and materials
Keywords
thermal conductivity, fused silica, crystalline quartz, temperature dependence, geothermal heat flux, heat flux measurement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›