Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 224

The DOI matches its Crossref record.

Pulse radiolysis apparatus

Keene, J P·1964·Journal of Scientific Instruments

Abstract

Apparatus for investigating the kinetics of radiation induced chemical reactions is described. It is used with a 4 Mev linear electron accelerator which is arranged to give any dose from a few tens of rads up to about 10 kilorads, to a small liquid sample in a single pulse lasting either 2.0 or 0.2 μsec. An optical system, in conjunction with a light source, a photodetector and a cathode-ray oscilloscope, is used to investigate the time variation in concentration of optically absorbing chemical species produced by the radiation. The importance of proper design of the optical system, if maximum sensitivity is required, is stressed. Shot noise in the photodetector is a natural limitation to the sensitivity of the method, when measurements are made in the microsecond region, and it is therefore necessary to get as much light as possible through the irradiation cell.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0950-7671/41/8/302

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 224

Metadata

Authors
Keene, J. P.
Venue
Journal of Scientific Instruments
Published
1964-08
Volume
41
Issue
8
Pages
493-496
ISSN
0950-7671 (ISSN-L)
OpenAlex
W2032326087
Cited by
224
References
0
FWCI
15.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulse radiolysis apparatus. https://app.cochat.ai/papers/10.1088/0950-7671/41/8/302
The paper
Keene, J. P. (1964). Pulse radiolysis apparatus. Journal of Scientific Instruments. https://doi.org/10.1088/0950-7671/41/8/302

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.