Recommended Standards For The Routine Performance Testing of Diagnostic X-Ray Imaging Systems
Abstract
The first edition of this report was published in 1997 and contained essential guidance on routine quality assurance of imaging performance and patient dose for all professionals with an interest and responsibility in diagnostic x-ray imaging systems. The 1998 edition contains minor corrections to a small number of test tolerances and references. The entire diagnostic x-ray imaging system is covered in the report with information on radiography, fluoroscopy, computed tomography, digital, dental and mammography equipment. Clear advice is presented on the tests to be performed and with what priority, that is, which tests are essential and which are desirable. The level of expertise required to perform each test is indicated and how regularly each test should be performed. More frequent tests do not require sophisticated test equipment and analysis whereas other tests involve greater expertise and equipment resources. Although the method of performing each test is not included, test references provide information on where instructions may be obtained. For many of the tests very useful guidance is provided as to when results indicate further action should be taken. In short, this publication provides (i) clarification of the 'what, who, when and how' of x-ray equipment testing. This enables a uniform testing regime to be carried out by radiographic staff, medical physics staff and service engineers. (ii) remedial and suspension levels which assist in the interpretation of measurements. This should result in improved diagnosis of equipment performance and reporting time. (iii) useful guidance to a wide range of professionals including employers, managers, users, inspectors, purchasers and suppliers. It has important implications particularly for employers since, legally, they have responsibility for ensuring that the equipment used in connection with medical exposures is maintained so as to be capable of delivering doses that are as low as reasonably practicable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Managing patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 375
ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology
Khong, P.-L., Ringertz, H., Donoghue, V., Frush, D., Rehani, M., Appelgate, K., & Sanchez, R. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.10.001 · Cited by 363
Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
154, I. P. (2023) · Annals of the ICRP · doi:10.1177/01466453231210646 · Cited by 37
Metadata
- Authors
- Evans, S.
- Venue
- Journal of Radiological Protection
- Publisher
- IOP Publishing
- Published
- 1998-06
- Volume
- 18
- Issue
- 2
- ISSN
- 0952-4746 (ISSN-L)
- 1361-6498
- OpenAlex
- W1965502991
- Cited by
- 159
- References
- 0
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recommended Standards For The Routine Performance Testing of Diagnostic X-Ray Imaging Systems. https://app.cochat.ai/papers/10.1088/0952-4746/18/2/023
- The paper
- Evans, S. (1998). Recommended Standards For The Routine Performance Testing of Diagnostic X-Ray Imaging Systems. Journal of Radiological Protection. https://doi.org/10.1088/0952-4746/18/2/023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.