Microwave engineering of plasma-assisted CVD reactors for diamond deposition
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The unique properties of CVD diamond make it a compelling choice for high power electronics. In order to achieve industrial use of CVD diamond, one must simultaneously obtain an excellent control of the film purity, very low defect content and a sufficiently rapid growth rate. Currently, only microwave plasma-assisted chemical vapour deposition (MPACVD) processes making use of resonant cavity systems provide enough atomic hydrogen to satisfy these requirements. We show in this paper that the use of high microwave power density (MWPD) plasmas is necessary to promote atomic hydrogen concentrations that are high enough to ensure the deposition of high purity diamond films at large growth rates. Moreover, the deposition of homogeneous films on large surfaces calls for the production of plasma with appropriate shapes and large volumes. The production of such plasmas needs generating a fairly high electric field over extended regions and requires a careful design of the MW coupling system, especially the cavity. As far as MW coupling efficiency is concerned, the presence of a plasma load represents a mismatching perturbation to the cavity. This perturbation is especially important at high MWPD where the reflected fraction of the input power may be quite high. This mismatch can lead to a pronounced heating of the reactor walls. It must therefore be taken into account from the very beginning of the reactor design. This requires the implementation of plasma modelling tools coupled to detailed electromagnetic simulations. This is discussed in section 3. We also briefly discuss the operating principles of the main commercial plasma reactors before introducing the reactor design methodology we have developed. Modelling results for a new generation of reactors developed at LIMHP, working at very high power density, will be presented. Lastly, we show that scaling up this type of reactor to lower frequencies (915 MHz) can result in high density plasmas allowing for fast and homogeneous diamond deposition on up to 160 mm diameter surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High Carrier Mobility in Single-Crystal Plasma-Deposited Diamond
Isberg, J., Hammersberg, J., Johansson, E., Wikström, T., Twitchen, D. J., Whitehead, A. J., Coe, S. E., & Scarsbrook, G. A. (2002) · Science · doi:10.1126/science.1074374 · Cited by 1,321
Mechanism for diamond growth from methyl radicals
Harris, S. J. (1990) · Applied Physics Letters · doi:10.1063/1.102946 · Cited by 396
Principles of plasma discharges and material processing
Keatch, R. P. (1996) · Microelectronics Journal · doi:10.1016/0026-2692(96)82781-9 · Cited by 325
Scaling laws for diamond chemical-vapor deposition. I. Diamond surface chemistry
Goodwin, D. G. (1993) · Journal of Applied Physics · doi:10.1063/1.355063 · Cited by 243
High quality MPACVD diamond single crystal growth: high microwave power density regime
Achard, J., Silva, F., Tallaire, A., Bonnin, X., Lombardi, G., Hassouni, K., & Gicquel, A. (2007) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/40/20/s04 · Cited by 200
Self-citationHassouni, K., Grotjohn, T. A., & Gicquel, A. (1999) · Journal of Applied Physics · doi:10.1063/1.370710 · Cited by 175
Self-citationHigh quality, large surface area, homoepitaxial MPACVD diamond growth
Silva, F., Achard, J., Brinza, O., Bonnin, X., Hassouni, K., Anthonis, A., Corte, K. D., & Barjon, J. (2009) · Diamond and Related Materials · doi:10.1016/j.diamond.2009.01.038 · Cited by 130
Self-citationSpectroscopic analysis and chemical kinetics modeling of a diamond deposition plasma reactor
Gicquel, A., Hassouni, K., Farhat, S., Breton, Y., Scott, C. D., Lefebvre, M., & Péalat, M. (1994) · Diamond and Related Materials · doi:10.1016/0925-9635(94)90229-1 · Cited by 102
Self-citationSimulation and development of optimized microwave plasma reactors for diamond deposition
Füner, M., Wild, C., & Koidl, P. (1999) · Surface and Coatings Technology · doi:10.1016/s0257-8972(99)00233-9 · Cited by 102
Interaction between the electromagnetic fields and the plasma in a microwave plasma reactor
Hagelaar, G. J. M., Hassouni, K., & Gicquel, A. (2004) · Journal of Applied Physics · doi:10.1063/1.1769607 · Cited by 73
Self-citation
Cited by
Cheng, Z., Bougher, T., Bai, T., Wang, S. Y., Li, C., Yates, L., Foley, B. M., Goorsky, M., Cola, B. A., Faili, F., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b16812 · Cited by 76
Colonna, G., Pintassilgo, C. D., Pegoraro, F., Cristofolini, A., Popoli, A., Neretti, G., Gicquel, A., Duigou, O., Bieber, T., Hassouni, K., et al. (2021) · The European Physical Journal D · doi:10.1140/epjd/s10053-021-00186-5 · Cited by 25
Self-citation
Metadata
- Authors
- Silva, F., Hassouni, K., Bonnin, X., & Gicquel, A.
- Venue
- Journal of Physics: Condensed Matter
- Publisher
- IOP Publishing
- Published
- 2009-08-19
- Volume
- 21
- Issue
- 36
- Pages
- 364202
- ISSN
- 0953-8984 (ISSN-L)
- 1361-648X
- OpenAlex
- W2024707364
- Cited by
- 176
- References
- 12
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.