The DOI matches its Crossref record.
Scalar calibration of vector magnetometers
Abstract
The calibration parameters of a vector magnetometer are estimated only by the use of a scalar reference magnetometer. The method presented in this paper differs from those previously reported in its linearized parametrization. This allows the determination of three offsets or signals in the absence of a magnetic field, three scale factors for normalization of the axes and three non-orthogonality angles which build up an orthogonal system intrinsically in the sensor. The advantage of this method compared with others lies in its linear least squares estimator, which finds independently and uniquely the parameters for a given data set. Therefore, a magnetometer may be characterized inexpensively in the Earth's magnetic-field environment. This procedure has been used successfully in the pre-flight calibration of the state-of-the-art magnetometers on board the magnetic mapping satellites Ørsted, Astrid-2, CHAMP and SAC-C. By using this method, full-Earth-field-range magnetometers (± 65536.0 nT) can be characterized down to an absolute precision of 0.5 nT, non-orthogonality of only 2 arcsec and a resolution of 0.2 nT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ripka, P. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(03)00094-3 · Cited by 352
The Magnetometer Instrument on MESSENGER
Anderson, B. J., Acuña, M. H., Lohr, D. A., Scheifele, J., Raval, A., Korth, H., & Slavin, J. A. (2007) · Space Science Reviews · doi:10.1007/s11214-007-9246-7 · Cited by 297
The STEREO/IMPACT Magnetic Field Experiment
Acuña, M. H., Curtis, D., Scheifele, J. L., Russell, C. T., Schroeder, P., Szabo, A., & Luhmann, J. G. (2008) · Space Science Reviews · doi:10.1007/s11214-007-9259-2 · Cited by 252
Baldi, T. L., Scheggi, S., Meli, L., Mohammadi, M., & Prattichizzo, D. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2017.2720667 · Cited by 96
Metadata
- Authors
- Merayo, J. M. G., Brauer, P., Primdahl, F., Petersen, J. R., & Nielsen, O. V.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2000-01-07
- Volume
- 11
- Issue
- 2
- Pages
- 120-132
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2090203009
- Cited by
- 241
- References
- 0
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scalar calibration of vector magnetometers. https://app.cochat.ai/papers/10.1088/0957-0233/11/2/304
- The paper
- Merayo, J. M. G., Brauer, P., Primdahl, F., Petersen, J. R., & Nielsen, O. V. (2000). Scalar calibration of vector magnetometers. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/11/2/304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.