The DOI matches its Crossref record.
Thermal conductivity of insulations using guarded hot plates, including recent developments and sources of reference materials
Open accessAbstract
The hot plate technique for measuring the thermal conductivities (the exact term for the quantity measured is thermal transmission, which, depending on the material being measured, can have components of convective, radiative and conductive heat transfer; it is commonly referred to as the effective or apparent thermal conductivity) of insulating materials has been in existence in various forms since 1898. A brief historical survey of the early development of the experimental technique is followed by a brief description of the basic principles of the method of measurement. The technique has since become very well established and is documented in the written standard ISO8302:1991. It is now unarguably recognized as the most accurate technique for determining the thermal conductivity of insulations, having an uncertainty of about 1.5% over a limited temperature range near ambient. Details of two guarded hot plate apparatuses designed and constructed at NPL over the last decade or so, one to measure insulations up to 250 mm thick at or around room temperature and the other to measure insulations and refractories at temperatures up to 850 °C, are given. Finally, there is a section on certified reference materials required for validating the performance of newly built guarded hot plate apparatus and for calibrating heat flow meter apparatus, a type of hot plate apparatus commonly used for quality control purposes in insulation manufacturing plant. A brief overview of these reference materials includes details of their availability, thermal conductivities and temperature ranges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Palacios, A., Cong, L., Navarro, M. E., Ding, Y., & Barreneche, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.03.020 · Cited by 237
Tendera, L., Wycisk, D., Gonzalez, C., Mertin, G. K., Pegel, H., & Birke, K. P. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2022.232120 · Cited by 24
Correct Use of the Guarded-Hot-Plate Method for Thermal Conductivity Measurements on Solids
Ebert, H.-P., & Vidi, S. (2024) · International Journal of Thermophysics · doi:10.1007/s10765-023-03307-x · Cited by 20
Metadata
- Authors
- Salmon, D.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2001-11-06
- Volume
- 12
- Issue
- 12
- Pages
- R89-R98
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2065998253
- Cited by
- 185
- References
- 0
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal conductivity of insulations using guarded hot plates, including recent developments and sources of reference materials. https://app.cochat.ai/papers/10.1088/0957-0233/12/12/201
- The paper
- Salmon, D. (2001). Thermal conductivity of insulations using guarded hot plates, including recent developments and sources of reference materials. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/12/12/201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.