Evaluation of effects of shear stress on hepatocytes by a microchip-based system
The DOI matches its Crossref record.
Abstract
A microchip-based evaluation system for the effects of shear stress on hepatocyte activity was developed. The shear flows caused hepatocytes to change morphology and functions according to their exposed value of shear stress. The metabolic activities of hepatocytes under higher shear stress were lower, especially when the cultivation time exceeded 3 days. The morphologic observation revealed that hepatocytes changed their shape like vascular endothelial cells do. This suggested that perfusion affected the function and morphology of hepatocytes in the microchip. This system is useful for the optimization of flow conditions in microfluidic bioreactors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
A microfluidic system to evaluate intestinal absorption
Imura, Y., Asano, Y., Sato, K., & Yoshimura, E. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1403 · Cited by 159
Self-citationMetabolic Patterning on a Chip: Towards in vitro Liver Zonation of Primary Rat and Human Hepatocytes
Kang, Y. B., Eo, J., Mert, S., Yarmush, M. L., & Usta, O. B. (2018) · Scientific Reports · doi:10.1038/s41598-018-27179-6 · Cited by 122
Metadata
- Authors
- Tanaka, Y., Yamato, M., Okano, T., Kitamori, T., & Sato, K.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2006-10-26
- Volume
- 17
- Issue
- 12
- Pages
- 3167-3170
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2061834863
- Cited by
- 107
- References
- 0
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of effects of shear stress on hepatocytes by a microchip-based system. https://app.cochat.ai/papers/10.1088/0957-0233/17/12/s08
- The paper
- Tanaka, Y., Yamato, M., Okano, T., Kitamori, T., & Sato, K. (2006). Evaluation of effects of shear stress on hepatocytes by a microchip-based system. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/17/12/s08
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.