Stereoscopic particle image velocimetry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The three components of the velocity field in a plane can be measured simultaneously by combining particle image velocimetry (PIV) and stereoscopy. A set-up has been devised to take two stereoscopic images of the flow simultaneously with only one camera, thus making automatic recording of three-dimensional (3D) velocity fields quite straightforward. Theoretical and practical considerations in implementing this stereoscopic PIV system are presented. The performance of the technique has been investigated by measuring several known displacements produced on a solid surface, and the application of the system to the measurement of the 3D velocity field in an acoustic streaming flow is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lighthill, S. J. (1978) · Journal of Sound and Vibration · doi:10.1016/0022-460x(78)90388-7 · Cited by 928
Cited by
Twenty years of particle image velocimetry
Adrian, R. J. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0991-7 · Cited by 1,267
Tomographic particle image velocimetry
Elsinga, G. E., Scarano, F., Wieneke, B., & van Oudheusden, B. W. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0212-z · Cited by 1,251
Distortion compensation for generalized stereoscopic particle image velocimetry
Soloff, S. M., Adrian, R. J., & Liu, Z.-C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/008 · Cited by 674
Cierpka, C., & Kähler, C. J. (2012) · Journal of Visualization · doi:10.1007/s12650-011-0107-9 · Cited by 450
Stereoscopic digital particle image velocimetry for application in wind tunnel flows
Willert, C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/010 · Cited by 387
Metadata
- Authors
- Arroyo, M. P., & Greated, C. A.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1991-12-01
- Volume
- 2
- Issue
- 12
- Pages
- 1181-1186
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2087027670
- Cited by
- 243
- References
- 1
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.