The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Electric current sensors: a review
Open accessAbstract
The review makes a brief overview of traditional methods of measurement of electric current and shows in more detail relatively new types of current sensors. These include Hall sensors with field concentrators, AMR current sensors, magneto-optical and superconducting current sensors. The influence of the magnetic core properties on the error of the current transformer shows why nanocrystalline materials are so advantageous for this application. Built-in CMOS current sensors are important tools for monitoring the health of integrated circuits. Of special industrial value are current clamps which can be installed without breaking the measured conductor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current Sensing Techniques: A Review
Ziegler, S., Woodward, R. C., Iu, H. H.-C., & Borle, L. J. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2013914 · Cited by 774
Using Rogowski coils for transient current measurements
Ward, D. A., & Exon, J. L. T. (1993) · Engineering Science and Education Journal · doi:10.1049/esej:19930034 · Cited by 280
A new battery model for use with battery energy storage systems and electric vehicles power systems
Chan, H. L. (2002) · 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077) · doi:10.1109/pesw.2000.850009 · Cited by 240
An overview of integratable current sensor technologies
Xiao, C., Zhao, L., Asada, T., Odendaal, W. G., & van Wyk, J. D. (2004) · Conference record · doi:10.1109/ias.2003.1257710 · Cited by 230
Designing a new generalized battery management system
Chatzakis, J., Kalaitzakis, K., Voulgaris, N. C., & Manias, S. N. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.817706 · Cited by 216
Integrated Hall-effect magnetic sensors
Popovic, R. S., Randjelovic, Z., & Manic, D. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00478-2 · Cited by 178
Edelstein, A. S. (2007) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/19/16/165217 · Cited by 139
Mohri, K., Panina, I. V., Uchiyama, T., Bushida, K., & Noda, M. (1995) · IEEE Transactions on Magnetics · doi:10.1109/20.364817 · Cited by 118
Highly Accurate Fiber-Optic DC Current Sensor for the Electrowinning Industry
Bohnert, K. M., Brändle, H., Brunzel, M., Gabus, P., & Guggenbach, P. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.887311 · Cited by 88
High-Performance Planar Isolated Current Sensor for Power Electronics Applications
Dalessandro, L., Karrer, N., & Kolar, J. W. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904198 · Cited by 80
Metadata
- Authors
- Ripka, P.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2010-09-24
- Volume
- 21
- Issue
- 11
- Pages
- 112001
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2021038552
- Cited by
- 278
- References
- 20
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric current sensors: a review. https://app.cochat.ai/papers/10.1088/0957-0233/21/11/112001
- The paper
- Ripka, P. (2010). Electric current sensors: a review. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/21/11/112001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.