CoChat

A review of reconstruction techniques for capacitance tomography

Isaksen, Øyvind · 1996 · Measurement Science and Technology
Cited by 267

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Capacitance tomography has been used to image several processes, such as liquid/gas pipe flow, oil/water/gas gravity separation, pneumatic conveying, fluidized beds and flame combustion. The nature of the capacitance sensors is such that reconstruction algorithms well developed for medical tomography are not applicable. The main problem is that the relationship between the measured quantity (capacitance) and the parameter of interest (distribution of the dielectric constant) is nonlinear. Furthermore, it is impossible to establish an explicit expression which relates the dielectric constant distribution to the measured capacitance. Also it should be pointed out that the number of measurements in capacitance tomography is small (typically less than 100) compared to medical tomography. For these reasons the first tested algorithm in capacitance tomography was based on the crude back projection algorithm. This algorithm has over the years been enhanced for use with a capacitance tomograph. In addition other techniques, such as various iterative methods, algorithms based on artificial neural networks and `look-up' tables have been developed and tested. This paper outlines the working principles for the different techniques and presents the main results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-0233/7/3/013

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Isaksen, Ø.
Venue
Measurement Science and Technology
Published
1996-03-01
Volume
7
Issue
3
Pages
325-337
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2060021325
Cited by
267
References
1
FWCI
5.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A review of reconstruction techniques for capacitance tomography. https://app.cochat.ai/papers/10.1088/0957-0233/7/3/013
The paper
Isaksen, Ø. (1996). A review of reconstruction techniques for capacitance tomography. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/7/3/013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.