A portable fracture toughness tester for biological materials
Abstract
A portable mechanical tester is described which is both lightweight and cheap to produce. The machine is simple and convenient to operate and requires only a minimum of personnel training. It can be used to measure the fundamental mechanical properties of pliant solids, particularly toughness (in the sense of `work of fracture') using either scissors or wedge tests. This is achieved through a novel hardware integration technique. The circuits are described. The use of the machine does not require a chart recorder but it can be linked to a personal computer, either to show force - displacement relationships or for data storage. The design allows the use of any relatively `soft' mechanical test, i.e. tests in which the deformability of the frame of the machine and its load cell do not introduce significant errors into the results. Examples of its use in measuring the toughness of biomaterials by scissors (paper, wood) and wedges (mung bean starch gels) are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dental Functional Morphology: How Teeth Work
Lucas, P. W. (2004) · doi:10.1017/cbo9780511735011 · Cited by 550
Self-citationLeaves at low versus high rainfall: coordination of structure, lifespan and physiology
Wright, I. J., & Westoby, M. (2002) · New Phytologist · doi:10.1046/j.1469-8137.2002.00479.x · Cited by 389
Metadata
- Authors
- Darvell, B. W., Lee, P. K. D., Yuen, T. D. B., & Lucas, P. W.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1996-06-01
- Volume
- 7
- Issue
- 6
- Pages
- 954-962
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2053461463
- Cited by
- 162
- References
- 0
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A portable fracture toughness tester for biological materials. https://app.cochat.ai/papers/10.1088/0957-0233/7/6/016
- The paper
- Darvell, B. W., Lee, P. K. D., Yuen, T. D. B., & Lucas, P. W. (1996). A portable fracture toughness tester for biological materials. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/7/6/016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.