Converting a positive operator-valued measure to a design for a measuring instrument on the laboratory bench
Abstract
A known positive operator-valued measure (POVM) describing a desired receiver of quantum light states is converted into a description of parts - including a prism, beam splitters and detectors - arranged to make a laboratory instrument. The conversion is made in two stages. The first is a transparent example of Neumark's theorem, in which a two-dimensional (non-projective) POVM is converted into a Hermitian operator on a space of three dimensions. The second uses a known factorization of the Hermitian operator into a product of simpler operators, each a conventional description of an optical component. If the components behave according to their conventional descriptions, the receiver behaves in accord with the given POVM.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Generalised measurements (POVMs) are useful when distinguishing between nonorthogonal states and can be implemented with N ports.
“These are particularly useful when we need to distinguish between nonorthogonal states, and they can be implemented with N ports as well (Myers and Brandt 1997).”
From Linear optical quantum computing with photonic qubits (2007) · cites this paper as Myers and Brandt 1997
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 8
- 10.1103/PhysRevA.54.3783 · DOI
- 10.1103/PhysRevLett.73.58 · DOI · Paper page
- 10.1103/PhysRevA.50.1047 · DOI
- Brandt H E, 1997, Proc. SPIE, 3076, 12, 10.1117/12.277651 · DOI
- 10.1016/0375-9601(88)91034-1 · DOI
- 10.1016/0375-9601(87)90222-2 · DOI
- 10.1103/PhysRevA.40.1371 · DOI
- Caves C M, 1980, Phys. Rev. Lett., 45, 78
Cited by
Sorted by citations
Linear optical quantum computing with photonic qubits
Kok, P., Munro, W. J., Nemoto, K., Ralph, T. C., Dowling, J. P., & Milburn, G. J. (2007) · Reviews of Modern Physics · doi:10.1103/revmodphys.79.135 · Cited by 2,904
Metadata
- Authors
- Myers, J. M., & Brandt, H. E.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1997-11-01
- Volume
- 8
- Issue
- 11
- Pages
- 1222-1227
- ISSN
- 0957-0233
- 1361-6501
- Cited by
- 20
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review