A 4.2 K receiver coil and SQUID amplifier used to improve the SNR of low-field magnetic resonance images of the human arm
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe the design and use of a 48 mm diameter, liquid-helium-cooled MRI receiver coil and DC SQUID pre-amplifier. Comparison of images of a non-conducting room temperature test object collected with the SQUID-based system and those collected with an equivalent-area room-temperature surface coil show that the SQUID system SNR is approximately a factor of four greater, despite a 15 mm vacuum gap between sample and coil in the SQUID case. SQUID images of the lower arm also display improved SNRs over those of the room-temperature coil, this time by a factor of between two and three, and as a result reveal greater anatomical detail. We show that the performance is currently limited by inductively coupled losses from metal components in the imager, but that, by using the same system in a whole-body imager, the SNR of SQUID images of the arm will exceed the room-temperature coil's performance by a factor of between 2.8 and 4.5. We believe that these are the first magnetic resonance images of a living sample to have been produced with a SQUID-based receiver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of a DC SQUID receiver preamplifier in a low field MRI system
Seton, H. C., Bussell, D. M., Hutchison, J. M. S., & Lurie, D. J. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.403276 · Cited by 28
Self-citation
Cited by
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Application of superconducting quantum interference devices to nuclear magnetic resonance
Greenberg, Y. S. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.175 · Cited by 214
Perspectives with cryogenic RF probes in biomedical MRI
Darrasse, L. (2003) · Biochimie · doi:10.1016/j.biochi.2003.09.016 · Cited by 201
SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT
Lee, S. K., Möβle, M., Myers, W., Kelso, N., Trabesinger, A. H., Pines, A., & Clarke, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20316 · Cited by 139
Nuclear magnetic resonance in the nanoTesla range
Burghoff, M., Hartwig, S., Trahms, L., & Bernarding, J. (2005) · Applied Physics Letters · doi:10.1063/1.2006981 · Cited by 101
Metadata
- Authors
- Seton, H. C., Hutchison, J. M. S., & Bussell, D. M.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1997-02-01
- Volume
- 8
- Issue
- 2
- Pages
- 198-207
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2092824410
- Cited by
- 71
- References
- 1
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.