The evaluation of standard uncertainty in the presence of limited resolution of indicating devices
Abstract
Since the type A evaluation of standard uncertainty according to the rules given in the ISO Guide to the Expression of Uncertainty in Measurement does not take into account the uncertainty that arises from the limited resolution of indicating devices, we show in this design note that the treatment of this problem calls for a quantity about which no statistical information is available; therefore, its uncertainty has to be derived from a type B evaluation.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Measurement errors in the optical constants obtained from THz-TDS have not been systematically analyzed.
“Nevertheless, measurement errors in the optical constants, so far, have not been systematically analyzed.”
From Uncertainty in terahertz time-domain spectroscopy measurement (2008) · cites this paper as [17]
Previous literature on uncertainty models for optical constants in THz-TDS considers only signal noise and/or does not extend the model into the time domain, and developed linear models are rarely verified by nonlinear numerical simulation.
“In those cases the work only considers the influence of signal noise and/or does not extend the model into the time domain. Furthermore, the developed linear models are rarely verified by a nonlinear numerical simulation.”
From Uncertainty in terahertz time-domain spectroscopy measurement (2008) · cites this paper as [17]
Cited by
Sorted by citations
Uncertainty in terahertz time-domain spectroscopy measurement
Withayachumnankul, W., Fischer, B. M., Lin, H., & Abbott, D. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001059 · Cited by 181 · see citing works
- Authors
- Lira, I. H., & Wöger, W.
- Affiliations
- Pontificia Universidad Católica de Chile (CL)
- Physikalisch-Technische Bundesanstalt (DE)
- ORCID
- Lira, Ignacio H
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1997-04-01
- Volume
- 8
- Issue
- 4
- Pages
- 441-443
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W1984476527
- Cited by
- 39
- References
- 0
- Citations by year
- 2023: 1 · 2022: 3 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 2 · 2014: 3 · 2013: 2 · 2012: 3
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Measurement Science and Technology (publishedVersion)
- Funders
- Comisión Nacional de Investigación Científica y Tecnológica
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- standard uncertainty, type B evaluation, Type A evaluation, measurement uncertainty, Guide to the Expression of Uncertainty in Measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review