Quantitative measurement of solvation shells using frequency modulated atomic force microscopy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The nanoscale specificity of interaction measurements and additional imaging capability of the atomic force microscope make it an ideal technique for measuring solvation shells in a variety of liquids next to a range of materials. Unfortunately, the widespread use of atomic force microscopy for the measurement of solvation shells has been limited by uncertainties over the dimensions, composition and durability of the tip during the measurements, and problems associated with quantitative force calibration of the most sensitive dynamic measurement techniques. We address both these issues by the combined use of carbon nanotube high aspect ratio probes and quantifying the highly sensitive frequency modulation (FM) detection technique using a recently developed analytical method. Due to the excellent reproducibility of the measurement technique, additional information regarding solvation shell size as a function of proximity to the surface has been obtained for two very different liquids. Further, it has been possible to identify differences between chemical and geometrical effects in the chosen systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Klein, J., & Kumacheva, E. (1998) · The Journal of Chemical Physics · doi:10.1063/1.476114 · Cited by 496
Cited by
Molecular Structure of Water at Interfaces: Wetting at the Nanometer Scale
Verdaguer, A., Sacha, G. M., Bluhm, H., & Salmeron, M. (2006) · Chemical Reviews · doi:10.1021/cr040376l · Cited by 627
Structured and viscous water in subnanometer gaps
Li, T.-D., Gao, J., Szoszkiewicz, R., Landman, U., & Riedo, E. (2007) · Physical Review B · doi:10.1103/physrevb.75.115415 · Cited by 359
Protons @ interfaces: Implications for biological energy conversion
Mulkidjanian, A. Y., Heberle, J., & Cherepanov, D. A. (2006) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2006.02.015 · Cited by 210
“In other words, the interfacial water tends to form layered structures, which were revealed by AFM [118,119] and by X-ray reflectivity [120].”
BackgroundAtomic- and Molecular-Resolution Mapping of Solid–Liquid Interfaces by 3D Atomic Force Microscopy
Fukuma, T., & Garcia, R. (2018) · ACS Nano · doi:10.1021/acsnano.8b07216 · Cited by 198
Dynamic Solidification in Nanoconfined Water Films
Khan, S. H., Matei, G., Patil, S., & Hoffmann, P. M. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.106101 · Cited by 162
Metadata
- Authors
- Uchihashi, T., Higgins, M., Nakayama, Y., Sader, J. E., & Jarvis, S. P.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2005-01-15
- Volume
- 16
- Issue
- 3
- Pages
- S49-S53
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W1978614860
- Cited by
- 68
- References
- 1
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative measurement of solvation shells using frequency modulated atomic force microscopy. https://app.cochat.ai/papers/10.1088/0957-4484/16/3/009
- The paper
- Uchihashi, T., Higgins, M., Nakayama, Y., Sader, J. E., & Jarvis, S. P. (2005). Quantitative measurement of solvation shells using frequency modulated atomic force microscopy. Nanotechnology. https://doi.org/10.1088/0957-4484/16/3/009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.