Atomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this study, we have investigated the performance of liquid-environment FM-AFM with various cantilevers having different dimensions from theoretical and experimental aspects. The results show that reduction of the cantilever dimensions provides improvement in the minimum detectable force as long as the tip height is sufficiently long compared with the width of the cantilever. However, we also found two important issues to be overcome to achieve this theoretically expected performance. The stable photothermal excitation of a small cantilever requires much higher pointing stability of the exciting laser beam than that for a long cantilever. We present a way to satisfy this stringent requirement using a temperature controlled laser diode module and a polarization-maintaining optical fiber. Another issue is associated with the tip. While a small carbon tip formed by electron beam deposition (EBD) is desirable for small cantilevers, we found that an EBD tip is not suitable for atomic-scale applications due to the weak tip-sample interaction. Here we show that the tip-sample interaction can be greatly enhanced by coating the tip with Si. With these improvements, we demonstrate atomic-resolution imaging of mica in liquid using a small cantilever with a megahertz-order resonance frequency. In addition, we experimentally demonstrate the improvement in the minimum detectable force obtained by the small cantilever in measurements of oscillatory hydration forces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fukuma, T., Ueda, Y., Yoshioka, S., & Asakawa, H. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.016101 · Cited by 464
Self-citation
Cited by
Gonella, G., Backus, E. H. G., Nagata, Y., Bonthuis, D. J., Loche, P., Schlaich, A., Netz, R. R., Kühnle, A., McCrum, I. T., Koper, M. T. M., et al. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00293-2 · Cited by 556
Atomic- and Molecular-Resolution Mapping of Solid–Liquid Interfaces by 3D Atomic Force Microscopy
Fukuma, T., & Garcia, R. (2018) · ACS Nano · doi:10.1021/acsnano.8b07216 · Cited by 198
Self-citationFukuma, T., Reischl, B., Kobayashi, N., Spijker, P., Canova, F. F., Miyazawa, K., & Foster, A. S. (2015) · Physical Review B · doi:10.1103/physrevb.92.155412 · Cited by 126
Self-citationMiyata, K., Tracey, J., Miyazawa, K., Haapasilta, V., Spijker, P., Kawagoe, Y., Foster, A. S., Tsukamoto, K., & Fukuma, T. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b00757 · Cited by 86
Self-citation
Metadata
- Authors
- Fukuma, T., Onishi, K., Kobayashi, N., Matsuki, A., & Asakawa, H.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2012-03-16
- Volume
- 23
- Issue
- 13
- Pages
- 135706
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W1965319562
- Cited by
- 79
- References
- 1
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies. https://app.cochat.ai/papers/10.1088/0957-4484/23/13/135706
- The paper
- Fukuma, T., Onishi, K., Kobayashi, N., Matsuki, A., & Asakawa, H. (2012). Atomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies. Nanotechnology. https://doi.org/10.1088/0957-4484/23/13/135706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.